A
Troubleshooting
A-32
6.315 : ZR torque origin incorrect setting
Code
: &H0006 &H013B
Meaning/Cause
a. Simultaneous return-to-origin was performed while the ZR-stroke end method was set.
b. R-axis stack was not set for the Z-axis.
c. Either Z or R-axis return-to-origin method was not set to the ZR-stroke end method.
d. Multiple Z-axis (or R-axis) return-to-origin methods were set to the ZR-stroke end method.
Action
a. Set the return-to-origin order correctly. (Simultaneous return-to-origin cannot be performed.)
b. Set the R-axis stack correctly.
c. Set both Z and R-axis return-to-origin methods to the ZR-stroke end method.
d. Set Z and R-axis one each for the ZR-stroke end method.
6.316 : Can't execute while motor power on
Code
: &H0006 &H013C
Meaning/Cause
The parameter that cannot be written in motor power off status was saved.
Action
Turn off the motor, and then save the parameter.
6.317 : Illegal origin method
Code
: &H0006 &H013D
Meaning/Cause
a. Performing return-to-origin (mark method) was attempted.
b. Only one of Z or R-axis is set to ZR-stroke end method.
Action
a. Perform absolute reset for axes of “Mark" method using the programming box or support software.
b. Set both Z and R-axis at "ZR-stroke end method".
6.319 : Can't change hand data
Code
: &H0006 &H013F
Meaning/Cause
a. Changing the hand setting that another robot is using was attempted.
b. Specifying the hand R for the robot without R-axis was attempted.
Action
a. Release the hand setting of the other robot.
b. Set blank for the fourth parameter of the target parameter.
6.321 : Illegal option slot no
Code
: &H0006 &H0141
Meaning/Cause
The specified option slot number is out of the range; between 1 and 4.
Action
Specify an option slot number between 1 and 4.
6.322 : Illegal calibration no
Code
: &H0006 &H0142
Meaning/Cause
The specified calibration number is out of the range; between 0 and 31.
Action
Specify a calibration number between 0 and 31.
6.399 : Can't execute while alarm
Code
: &H0006 &H018F
Meaning/Cause
The program cannot be executed while an alarm is occurring.
Action
Clear the alarm cause and reset alarm or restart the controller as necessary.
Summary of Contents for R6YXC1000
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 86 5 6 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 54: ......
Page 56: ......
Page 64: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 108: ......
Page 110: ......
Page 136: ......
Page 168: ......
Page 170: ......
Page 174: ...8 Periodic inspection 8 4...
Page 176: ......
Page 182: ......
Page 256: ......
Page 258: ......
Page 259: ......
Page 260: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...