The device names are set in the slave parameters.
The default device names are E followed by a serial number that starts from 001.
For example, this method can be used to register device variables in the following cases.
• To eliminate the work that is involved in obtaining the device variable names.
Use the following procedure.
1
Double-click
I/O Map
under
Configurations and Setup
on the Multiview Explorer. Or, right-
click
I/O Map
under
Configurations and Setup
and select
Edit
.
The I/O Map Tab Page will be displayed.
2
Select a slave or I/O ports on the I/O Map Tab Page, right-click, and select
Create Device
Variable
.
Device variables that were automatically created
3
If you specify a variable table for the scope, specify the
Variable Type
afterward.
5 Setting Up EtherCAT Communications with the Sysmac Studio
5-12
NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (W505)