217
Built-in Outputs
Section 7-1
Ladder Program
Cyclic Task Program
(Executed at Startup)
Program for Interrupt Task
140
Enabling Input Interrupt 0 (IN0)
First Cycle Flag
Feeding Material with Speed Control
Material feed start
Material being fed
Material
positioning
completed
Emergency Stop (Pulse Output Stopped)
Emergency stop
switch
Pulse output completed
Pulse output in progress
First word containing new PV
Control data
Operation Mode Control
Port setting
Material positioning completed
Target frequency
First word containing control data
Mode setting
Frequence Acceleration/ Deceleration Control
Port setting
Material being fed
Control data 2
Interrupt Mask Setting
Control data 1
First word containing
start frequency
First word containing
parameters
Control data
Positioning
Port setting
Always ON
Flag
Interrupt Task for Marker Sensor ON
Starting Interrupt Feed