Remote controller

BRC1D517

OPERATION MANUAL

Switching from limit operation mode to automatic operation mode (heat pump models only) 
is not supported for Sky Air indoor models.

Summary of Contents for BRC1D517

Page 1: ...Remote controller BRC1D517 OPERATION MANUAL Switching from limit operation mode to automatic operation mode heat pump models only is not supported for Sky Air indoor models...

Page 2: ...1 1 1 2 9 3 25 22 11 10 37 35 27 26 12 14 17 34 24 5 20 21 18 16 13 15 19 32 31 30 29 28 4 36 33 8 23 7 6...

Page 3: ...2 2 Start 5s 5s 5s 5s 5s End...

Page 4: ...ume adjustment air flow direction adjustment 2 CLOCK FUNCTION The clock functions are 24 hours real time clock day of the week indicator 3 SCHEDULE TIMER FUNCTION The schedule timer functions are a ma...

Page 5: ...ventilation icon appears when the ventilation is adjusted with the ventilation amount button only Simultaneously the ventilation amount is indicated by the fan speed icon see 22 6 AIR CLEANING ICON Th...

Page 6: ...s only 20 AIR FLOW DIRECTION ICON This icon indicates the air flow direction only for installations with motorised air flow flaps 21 NOT AVAILABLE is displayed whenever a non installed option is addre...

Page 7: ...After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to operate the installation automatically setting the c...

Page 8: ...reached and is displayed This prevents cold air from leaving the indoor unit Defrost heat pump types only In heating operation freezing of the outdoor heat exchanger may occur If so the heating capac...

Page 9: ...TION User adjustable parameters Setpoint temperature use the buttons Fan speed use the button Air flow direction adjust use the button Ventilation mode use the button Ventilation amount use the button...

Page 10: ...the schedule timer Use the button to enable or disable the schedule timer To set up the SCHEDULE TIMER refer to chapter 6 Programming the schedule timer on page 10 KEEP IN MIND THAT THE BUTTON MUST BE...

Page 11: ...at will the schedule timer NOT do The schedule timer will not control fan speed control air flow direction control ventilation mode control ventilation amount change the operation mode for a scheduled...

Page 12: ...day not blinking you have now quit browsing How do I interpret the programmed actions To be able to understand the behaviour of your installation when the schedule timer is enabled it is important to...

Page 13: ...amming steps are limited to a minimum Below are some tips and tricks to ensure successful programming of the schedule timer familiarise yourself with the icons and the buttons you will need them when...

Page 14: ...in limit operation the selected temperature will blink Enter the time when the action must start using the buttons min step 10 minutes NOTE When changing day during programming you will have to confir...

Page 15: ...d if no actions were copied from Monday to Tuesday 2 I WANT TO EDIT PROGRAMMED ACTIONS Editing programmed actions is easy Make sure you are not in program mode not blinking if required press the butto...

Page 16: ...lp to solve your problem If you cannot remedy the problem consult your installer No readings on the remote controller display blank Check if the mains power is still applied to your installation Only...

Page 17: ...NOTES...

Page 18: ......

Page 19: ......

Page 20: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN15196 1A...