171
Origin Search and Origin Return Functions
Section 6-3
Pulse Output 1 Limit Input Signal Operation
(CJ1M CPU Unit Ver. 2.0 Only)
Specify in the following PLC Setup settings whether to undefine the origin
when a CW/CCW limit input signal turns ON.
Pulse Output 0 Undefine Origin Setting (CJ1M CPU Unit Ver. 2.0 Only)
Pulse Output 1 Undefine Origin Setting (CJ1M CPU Unit Ver. 2.0 Only)
Acceleration/Deceleration
Curve Settings
Pulse Output 0 Speed Curve (CJ1M CPU Unit Ver. 2.0 Only)
Pulse Output 1 Speed Curve (CJ1M CPU Unit Ver. 2.0 Only)
Note
The acceleration/deceleration curve setting applies to all pulse outputs, not
just to origin searches. Refer to
S-curve Acceleration/Deceleration
page 162 for details.
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
274
04 to 07 0 hex: Search
only
1 hex: Always
0 hex
Specifies whether to use the CW/
CCW limit input signals (reflected in
A54008, A54009, A54108, and
A54109) only for origin searches or
for all pulse output functions.
---
When power is
turned ON
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
268
12 to 15 0 hex: Hold
1 hex: Undefine
0 hex
Specifies whether to hold the origin
setting when the CW/CCW limit input
signal is input during execution of an
origin search or pulse output function.
---
When operation
starts
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
286
12 to 15 0 hex: Hold
1 hex: Undefine
0 hex
Specifies whether to hold the origin
setting when the CW/CCW limit input
signal is input during execution of an
origin search or pulse output function.
---
When operation
starts
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
256
12 to 15 0 hex: Trapezium
(linear)
1 hex: S-shaped
0 hex
Specifies whether to use S-curve or
linear acceleration/deceleration rates
for pulse outputs with acceleration/
deceleration.
---
When power is
turned ON
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
274
12 to 15 0 hex: Trapezium
(linear)
1 hex: S-shaped
0 hex
Specifies whether to use S-curve or
linear acceleration/deceleration rates
for pulse outputs with acceleration/
deceleration.
---
When power is
turned ON
Summary of Contents for CJ1M-CPU21
Page 1: ...Cat No W395 E1 03 CJ series Built in I O CJ1M CPU21 22 23 CJ1M CPU Units...
Page 2: ...CJ series Built in I O CJ1M CPU21 22 23 CPU Units Operation Manual Revised August 2004...
Page 3: ...iv...
Page 19: ...xx...
Page 79: ...50 Wiring Examples Section 3 3...
Page 217: ...188 Origin Search and Origin Return Functions Section 6 3...
Page 220: ...191 Built in Outputs Section 7 1...
Page 247: ...218 Built in Outputs Section 7 1...
Page 251: ...222 Combinations of Pulse Control Instructions Appendix A...
Page 255: ...226 Using Pulse Instructions in other CPU Units Appendix B...
Page 263: ...234 Index...
Page 265: ...236 Revision History...