![Omron CJ1M-CPU21 Operation Manual Download Page 93](http://html1.mh-extra.com/html/omron/cj1m-cpu21/cj1m-cpu21_operation-manual_742493093.webp)
64
PLC Setup Settings
Section 4-2
Pulse Output 1 Origin Proximity Input Signal Type
Pulse Output 1 Limit Input Signal Type
Pulse Output 1 Origin Search/Return Initial Speed
Note
When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Pulse Output 1 Origin Search High Speed
Note
When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Pulse Output 1 Origin Search Proximity Speed
Note
When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
286
04 to 07 0 hex: NC
1 hex: NO
0 hex
Specifies whether the Origin Proxim-
ity Input Signal for pulse output 1 is
normally closed or normally open.
---
When operation
starts
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
286
00 to 03 0 hex: NC
1 hex: NO
0 hex
Specifies whether the limit input sig-
nal for pulse output 1 is normally
closed or normally open.
---
When operation
starts
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
276
00 to 15 00000000 to
000186A0 hex
(See note.)
00000000
hex
Specifies the starting speed (0 to
100,000 pps) for the pulse output 1
origin search and origin return opera-
tions.
---
When operation
starts
277
00 to 15
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
278
00 to 15 00000001 to
000186A0 hex
(See note.)
00000001
hex
Specifies the high speed setting (1 to
100,000 pps) for pulse output 1 origin
search operation.
---
When operation
starts
279
00 to 15
Programming
Console setting
address
Settings
Default
Function
Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word
Bits
280
00 to 15 00000001 to
000186A0 hex
(See note.)
00000000
hex
Specifies the proximity speed setting
(1 to 100,000 pps) for pulse output 1
origin search operation.
---
When operation
starts
281
00 to 15
Summary of Contents for CJ1M-CPU21
Page 1: ...Cat No W395 E1 03 CJ series Built in I O CJ1M CPU21 22 23 CJ1M CPU Units...
Page 2: ...CJ series Built in I O CJ1M CPU21 22 23 CPU Units Operation Manual Revised August 2004...
Page 3: ...iv...
Page 19: ...xx...
Page 79: ...50 Wiring Examples Section 3 3...
Page 217: ...188 Origin Search and Origin Return Functions Section 6 3...
Page 220: ...191 Built in Outputs Section 7 1...
Page 247: ...218 Built in Outputs Section 7 1...
Page 251: ...222 Combinations of Pulse Control Instructions Appendix A...
Page 255: ...226 Using Pulse Instructions in other CPU Units Appendix B...
Page 263: ...234 Index...
Page 265: ...236 Revision History...