144
Built-in Outputs
Section 6-2
Bit Allocations
Pulse Output Specifications
Code
Word
address
Bit
CW/CCW inputs
Pulse + direction inputs
OUT0
CIO 2961
00
Pulse output 0 (CW)
Pulse output 0 (pulse)
OUT1
01
Pulse output 0 (CCW)
Pulse output 1 (pulse)
OUT2
02
Pulse output 1 (CW)
Pulse output 0 (direction)
OUT3
03
Pulse output 1 (CCW)
Pulse output 1 (direction)
Item
Specifications
Output mode
Continuous mode (for speed control) or independent
mode (for position control)
Positioning (independent
mode) instructions
PULS(886) and SPED(885), PULS(886) and
ACC(888), or PLS2(887)
Speed control (continuous
mode) instructions
SPED(885) or ACC(888)
Origin (origin search and ori-
gin return) instructions
ORG(889)
Output frequency
1 Hz to 100 kHz (1 Hz units)
Acceleration and deceleration
rates
Set in 1 Hz units for acceleration/deceleration rates
from 1 Hz to 2 kHz (every 4 ms). The acceleration
and deceleration rates can be set independently only
with PLS2(887).
Changing SVs during instruc-
tion execution
The target frequency, acceleration/deceleration rate,
and target position can be changed.
Duty ratio
Fixed at 50%
Pulse output method
CW/CCW inputs or Pulse + direction inputs
The method is selected with an instruction operand.
The same method must be used for pulse outputs 0
and 1.
Number of output pulses
Relative coordinates: 00000000 to 7FFFFFFF hex
(Each direction accelerating or decelerating:
2,147,483,647)
Absolute coordinates: 80000000 to 7FFFFFFF hex
(
−
2147483648 to 2147483647)
Pulse output PV's relative/
absolute coordinate specifica-
tion
Absolute coordinates are specified automatically
when the origin location has been determined by set-
ting the pulse output PV with INI(880) or performing
an origin search with ORG(889). Relative coordi-
nates are used when the origin location is undeter-
mined.
Relative pulse specification/
Absolute pulse specification
The pulse type can be specified with an operand in
PULS(886) or PLS2(887).
Note
The absolute pulse specification can be used when
absolute coordinates are specified for the pulse out-
put PV, i.e. the origin location has been determined.
The absolute pulse specification cannot be used
when relative coordinates are specified, i.e. the origin
location is undetermined. An instruction error will
occur.
Summary of Contents for CJ1M-CPU21
Page 1: ...Cat No W395 E1 03 CJ series Built in I O CJ1M CPU21 22 23 CJ1M CPU Units...
Page 2: ...CJ series Built in I O CJ1M CPU21 22 23 CPU Units Operation Manual Revised August 2004...
Page 3: ...iv...
Page 19: ...xx...
Page 79: ...50 Wiring Examples Section 3 3...
Page 217: ...188 Origin Search and Origin Return Functions Section 6 3...
Page 220: ...191 Built in Outputs Section 7 1...
Page 247: ...218 Built in Outputs Section 7 1...
Page 251: ...222 Combinations of Pulse Control Instructions Appendix A...
Page 255: ...226 Using Pulse Instructions in other CPU Units Appendix B...
Page 263: ...234 Index...
Page 265: ...236 Revision History...