![background image](http://html1.mh-extra.com/html/omron/cj1m-cpu21/cj1m-cpu21_operation-manual_742493234.webp)
205
Built-in Outputs
Section 7-1
Preparation
PLC Setup Settings
Note
The origin search enable setting is read when the power supply is turned ON.
DM Area Settings
Settings for PLS2(887) for Fixed-distance Positioning (D00000 to D00007)
Settings for PLS2(887) to Return to Start (D00010 to D00017)
Number of Repeats of Fixed-distance Positioning Operation (D00020)
Setting details
Address
Data
Enable origin search function for pulse output 0.
256
0001 hex
Setting details
Address
Data
Acceleration rate: 1,000 Hz/4 ms
D00000
#03E8
Deceleration rate: 1,000 Hz/4 ms
D00001
#03E8
Target frequency: 50,000 Hz
D00002
#C350
D00003
#0000
Number of output pulses: 10,000 pulses
D00004
#2710
D00005
#0000
Starting frequency: 0 Hz
D00006
#0000
D00007
#0000
Setting details
Address
Data
Acceleration rate: 300 Hz/4 ms
D00010
#012C
Deceleration rate: 200 Hz/4 ms
D00011
#00C8
Target frequency: 50,000 Hz
D00012
#C350
D00013
#0000
Number of output pulses: 10,000
×
15 pulses
D00014
#49F0
D00015
#0002
Starting frequency: 100 Hz
D00016
#0000
D00017
#0000
Setting details
Address
Data
Number of repeats of fixed-distance positioning operation
(number of PCBs in stocker)
D00020
#0015
Summary of Contents for CJ1M-CPU21
Page 1: ...Cat No W395 E1 03 CJ series Built in I O CJ1M CPU21 22 23 CJ1M CPU Units...
Page 2: ...CJ series Built in I O CJ1M CPU21 22 23 CPU Units Operation Manual Revised August 2004...
Page 3: ...iv...
Page 19: ...xx...
Page 79: ...50 Wiring Examples Section 3 3...
Page 217: ...188 Origin Search and Origin Return Functions Section 6 3...
Page 220: ...191 Built in Outputs Section 7 1...
Page 247: ...218 Built in Outputs Section 7 1...
Page 251: ...222 Combinations of Pulse Control Instructions Appendix A...
Page 255: ...226 Using Pulse Instructions in other CPU Units Appendix B...
Page 263: ...234 Index...
Page 265: ...236 Revision History...