background image

Wired Remote 

Controller

Operation Manual

• Thank you for choosing this wired remote controller.

• This manual describes safety measures which should be considered during for 

using this product. 

Please read and understand this manual thoroughly and be sure you are 

understand the information provided before using the product. 

Keep manual where user can be accessible easily.

MODEL  BRC1H71W

+

-

English

01_EN_EM19A027_OP.indd   1

2020/09/08   14:29:21

Summary of Contents for BRC1H71W

Page 1: ...fety measures which should be considered during for using this product Please read and understand this manual thoroughly and be sure you are understand the information provided before using the produc...

Page 2: ...01_EN_EM19A027_OP indd 2 2020 09 08 14 29 21...

Page 3: ...Airflow 18 Energy Recovery Ventilator ERV 21 LED Brightness Light Ring On 23 LED Brightness Light Ring Off 24 Setpoint 25 Fahrenheit Celsius 26 Administrator menu 27 Backlight brightness Contrast 28 C...

Page 4: ...damage accidents only The following pictograms are used in this manual Never do Always follow the instructions given Keep water and moisture away Keep wet hands away WARNING Do not modify or repair t...

Page 5: ...electric shocks or fire Never let the remote controller to get wet Water can cause damage to the remote controller and may cause an electric shock or fire NOTE Never press the buttons of the remote c...

Page 6: ...ss this button again to turn off the system b Status indicator LED During operation the light ring around the display lights up blue red green Lights up blue Operating Blinks red Error is occurring Li...

Page 7: ...ich can be selected Administrator menu Information screen Bluetooth Setting This screen is a menu for the administrator See the next page for items which can be selected 12 34 A3 01 Unit 00 This scree...

Page 8: ...nds on current setting Ventilation Rate Ventilation rate setting Adjust LED ON LED brightness adjustment when backlight lights up Adjust LED OFF LED brightness adjustment when backlight lights up diml...

Page 9: ...ndoor unit on the system has the authority to change the operation mode between cool and heat i Under centralized control Displayed if the system is under the management of a multi zone controller Opt...

Page 10: ...con mode 73 F 74 Text mode Scale screen Auto Cool Cool Warm Icon mode Scale screen When in the scale screen the setpoint can be changed in the range of 3 C F of the reference temperature The reference...

Page 11: ...3 Room 73 F 74 Text mode Icon mode Press and hold on the Home screen for 5 seconds Information screen 12 34 The screen switches to the Information screen How to exit the information screen Information...

Page 12: ...ote controller has master control Able to select heating cooling operation Backup Indicates that backup operation is being carried out Energy savings Indicates that the system s energy consumption is...

Page 13: ...e setpoint screen Auto Cool Set 74 Auto Cool Set 72 Press or to adjust the setpoint When the indoor unit is turned off even if or are pressed or the have screen the setpoint dose not change Result The...

Page 14: ...not change Result The indoor unit changes temperature equal to the setpoint value When returning to the home screen Change setpoint screen Auto Cool 73 Room 73 F 74 Text mode Icon mode Press If there...

Page 15: ...screen Operation Mode Text mode Icon mode The screen switches to the user menu screen How to exit the user menu User menu screen Return Text mode Icon mode Press or to select Return or then press to a...

Page 16: ...ate through may look different from that represented menus this manual The controller only allows for basic operation of the system For advanced operation setback etc see in mobile application How to...

Page 17: ...and space comfort Defrost operation The system will automatically go into defrost operation to prevent frost accumulation at the outdoor unit and subsequent loss of heating capacity The indoor unit fa...

Page 18: ...n speed menu Depending on the system this function may not be displayed Fan speed screen The setting of the fan speeds will vary based upon the indoor unit model Press or to adjust the fan speed and t...

Page 19: ...n speed mode If fan stops operating always not mean system failure The fan can stop operating at any time There may be a delay between the fan speed setting made on the controller and the change actua...

Page 20: ...his function may not be displayed Airflow direction screen Press or to adjust the airflow direction and press to confirm Airflow direction setting up down Position 0 Auto Position 1 Swing Position 2 P...

Page 21: ...changes its airflow direction and the controller returns to the home screen Automatic airflow control In the following operating conditions the airflow direction of the indoor units is controlled auto...

Page 22: ...ction menu and decide on an left right direction via the vertical airflow menu User menu screen Vertical Air ow Text mode Icon mode Navigate to the vertical airflow menu Vertical airflow screen Vertic...

Page 23: ...e ventilation mode menu Depending on the system this function may not be displayed Ventilation mode screen Auto Text mode Icon mode Press or to adjust the ventilation mode and press to confirm Auto ER...

Page 24: ...rate menu Depending on the system this function may not be displayed Ventilation rate screen Press or to adjust the ventilation rate and press to confirm 2 fan speeds Auto Low High Result The indoor...

Page 25: ...mode Icon mode Access to the Adjust LED ON menu Adjust LED brightness during backlight ON Adjust LED ON Text mode Icon mode Press or to adjust the brightness of the ring around the remote controller t...

Page 26: ...OFF Text mode Icon mode Access to the Adjust LED OFF menu Adjust LED brightness during backlight OFF Adjust LED OFF Text mode Icon mode Press or to adjust the brightness of the ring around the remote...

Page 27: ...r to select the setting items then press to select the item Dual setpoint screen Cool 75 F Heat 72 F Set Cancel 75 F 72 F Text mode Icon mode Press or to change the setpoint then press to apply Dual s...

Page 28: ...mode Access to the Fahrenheit Celsius menu Fahrenheit Celsius screen Fahrenheit Text mode Icon mode Press or to choose a display method then press to apply Result The temperature is displayed in the m...

Page 29: ...e information screen for 5 seconds Administrator menu screen Bluetooth Setting Text mode Icon mode The screen switches to the Administrator menu screen How to exit the administrator menu Administrator...

Page 30: ...level then press to apply Result The backlight brightness is changed and the controller returns to the administrator menu screen How to set the contrast Administrator menu screen Contrast Text mode Ic...

Page 31: ...e clock setting menu Clock setting screen 2020 01 01 00 00 Edit 2020 01 01 00 00 Text mode Icon mode When changing the date if button is pressed the year will be selected Clock setting screen 2020 01...

Page 32: ...020 07 24 03 00 Press or button set the minute then press to move to the next field Clock setting screen Text mode Icon mode 2020 07 24 03 45 Edit 2020 07 24 03 45 When every setting from the year to...

Page 33: ...f it is connecting to the device for the first time Administrator menu screen Bluetooth Setting Text mode Icon mode Access to the Bluetooth setting menu Bluetooth setting screen 12 34 56 Press the but...

Page 34: ...beginning Result When setting is complete if operation is in progress the status indicator LED lights up green stopped it blinks green and the controller returns to the home screen The remote control...

Page 35: ...n and the controller returns to the menu screen Press the button and the bonding information is deleted If Bluetooth connection was not successful please delete the bonding information once and then t...

Page 36: ...ppeared The Administrator about screen has 2 pages Press the button to scroll through the pages Press the button to return Result The controller returns to the administrator menu screen About the info...

Page 37: ...field setting from the remote controller side is impossible Disconnect Bluetooth or perform field setting from the mobile application Sub menu screen Text mode Icon mode Disable 0 0 0 0 Set Cancel 0...

Page 38: ...n Sub menu screen 1 2 3 4 Set Cancel Enable 1 2 3 4 Text mode Icon mode Press or button select Set or and then press button to return to the installer menu If Enable Disable is set to Enable the set 4...

Page 39: ...mode Icon mode Press or to select the setting items then press to select the item Dual setpoint screen Cool 75 F Heat 72 F Set Cancel 75 F 72 F Text mode Icon mode Press or to change the setpoint then...

Page 40: ...any moisture NOTICE Do not use any paint thinner organic solvent or strong acid Indoor unit error code Home screen Auto Cool 73 Room When the indoor unit is in error the controller will display on the...

Page 41: ...displayed on the Home screen filter maintenance is necessary User menu screen Sign Reset Text mode Icon mode Access to the filter sign menu User menu screen Filter Reset Text mode Icon mode The icons...

Page 42: ...troller returns to the home screen Filter sign screen When there is only a filter Filter Reset Text mode Icon mode Filter sign screen When there is only an element Element Reset Text mode Icon mode Du...

Page 43: ...operation manual Filter Change sign screen Filter Change Reset Text mode Icon mode Reset the filter indicator when the filter is replaced Press to apply Result The filter sign will disappeared and the...

Page 44: ...te controller and the SUB remote controller occurs so the SUB remote controller cannot be operated for about 10 seconds This does not occur at the 2nd and subsequent changes During setback operation i...

Page 45: ...fire Consult your Daikin dealer Advise your Daikin Dealer of the following items Model name Date of installation Failure conditions As precise as possible Your address name and telephone number Repair...

Page 46: ...EM19A027 2009 HT 01_EN_EM19A027_OP indd 44 2020 09 08 14 29 38...