3.1 Panel Component Names and Functions
3-2
ZM2371/ZM2372
3.1 Panel Component Names and Functions
This section describes the names and functions of the components on the front and rear
panel of
ZM2371 / ZM2372
.
Figure 3
–1 Front panel
Correction
OPEN, SHORT, LOAD, CABLE
Comparator/Handler interface
COMPRTR, Pri/Sec, NO LIMIT,
Settings and correction value
memories
SAVE, RECALL
Other operations
INIT
Initialize
SYSTEM
System setting
Contact check setting
With the
setting menu,
PREV: Previous
page
NEXT: Next page
EXIT: Close
Status indication lamps
Light up when:
AUTO CKT: Automatic selection of equivalent
circuit is enabled.
COMPRTR: Comparator is valid.
BUSY: Measurement is underway.
: Contact check is enabled.
BIAS ON: DC bias voltage output is underway.
SOURCE SYNC: Triggered drive is enabled.
KEY LOCK: Disables key operations
REMOTE: Remote control is underway.
Display
40-character
2-line LCD display.
1st line: Measured value (primary and secondary
parameters) and measurement frequency
When the comparator is enabled, the comparator result is
also displayed.
(
▲: > Upper limit, ▼: < Lower limit)
2nd line: Status, DC bias voltage, measurement signal level
The status can be switched to IV monitor, etc.
When detailed setting is made, the entire display switches
to the setting menu.
Status (2nd line)
RANGE: Auto / Hold and
measurement range
SPEED: FAST / MED / SLOW, etc.
AVERAGE: Averaging count
TRIG SOURCE: INT / MAN / EXT, etc.
CORRECTION:
Op (OPEN)
Sh (SHORT)
Ld (LOAD)
(Cable length)
0m / 1m / 2m / 4m
Register keys
0 .. 9 Number
・
Decimal point
-
Negative sign
EXP
Exponential part
( p n µ m k M)
BS(Back Space)
ENTR(Enter)
<Secondary function>
CE(Clear Entry)
Grounding
terminal for
measurement
Connected to the
case. Used for
shielding the DUT.
Measurement terminals
BNC connector comprising a set of 4-terminal-pair connected to
the device under test (DUT).
H
CUR
: Outputs signals to drive the DUT.
H
POT
, L
POT
: Measures voltage applied to the DUT.
L
CUR
: Measures current flowing in the DUT.
Connect all external conductors (shields) of 4 cables.
SHIFT key
Enables the secondary functions written
above each key.
LOCAL key
Restores local operation from remote state.
KEY LOCK: Disables key operations
<Secondary function>
Measurement condition setting keys
FREQ: Sets frequency
<Secondary function>
LEVEL: Sets signal level ..................... ALC: Sets constant voltage /
Constant current
SPEED: Sets measurement speed ..... AVERAGE: Sets averaging
TRIG: Manual trigger .......................... TRIG MODE: Sets trigger mode
AUTO/HOLD: Range auto/manual ...... RANGE: Sets measurement range
BIAS: Sets DC bias
S
e
c
o
n
d
a
ry
fu
n
c
ti
o
n
Tertiary
function
Display setting keys
<Secondary function>
Pri: Selects primary
parameters ..................
Δ
Pri: Sets deviation display
Sec: Selects secondary
parameters .................
Δ
Sec: Sets deviation display
CKT: Selects equivalent circuit
AUX DISP: Auxiliary display (status, etc. on 2nd line)