Chapter 4 - 198
Features
NEC Business Solutions Ltd
XEN Topaz
Doc. No. 8
846 - Re
lease 2.0
April 2005
Assign each extension a Calling Party Number (maximum 16 digits per
entry). The calling number is the subscriber number of the dial-in num-
ber. When a call is made by an extension which does not have an
Extension Calling Number assigned (Program 21-12), the system sends
the calling number for the ISDN trunk defined in Program 21-13.
Note:
If
the Calling Party Number is assigned in both Programs 21-12 and 21-
13, the system sends the data in Program 21-13.
22-02-01: Incoming Call Trunk Setup
Assign the incoming trunk type for each trunk. There is one item for each
Night Service Mode.
22-09 : Incoming Call Setup – DID Basic Data Setup
For each trunk group, define the basic setting of Dial-In incoming calls
for each trunk group.
22-09-01 :
Expected Number of Digits from Telco (1-8)
22-09-02 :
Received Vacant Number Operation (Disconnect, Transfer)
22-09-03 :
Sub-addressing Mode (Extension Number specify, DID Con-
version Table)
22-09-04 :
DID Receiving Mode for ISDN (Enbloc Receiving, Overlap
Receiving)
22-09-05 :
Local Code Digits (0-15)
22-09-06 :
Local Code (Max. 16 digits)
22-09-07 :
Pilot Code (1 digit, 0-9)
22-09-08 :
T302 Time-out Operation (Disconnect, Transfer)
22-11-01: DID Translation Table Number Conversion
Specify for each Translation Table entry (2000):
1 The digits received by the system (eight max.)
2 The extension the system dials after translation (24 digits max.)
3 The name that should show on the dialled extension’s display when it
rings (twelve characters max.)
4 The Transfer Target - 1 and 2. If the Transfer Targets are busy or receive
no answer, those calls are transferred to the final transfer destination (Pro-
gram 2-10).
5 Operation
mode
Assigning an ISDN Interface as an S-Bus Extension
In the following example, BRI Interface 1 will be assigned as an S-Bus extension.
Connected to this S-Bus port may be a video conference unit, G4 fax machine or other
ISDN device. Switch and Jumper settings referred to are located on the 2/4BRIU card.
Setup:
1. Set switch SW102 = S.
2. Set switch SW100 = ON.
3. Set both jumpers of CN102 = ON.
4. Assign Program 10-03-01 for BRI Interface 1 = S-Point.
5. If the cable length to the S-Bus device is between 200m and 500m, set Program 10-03-06 =
0. Otherwise leave at default (1).