![background image](http://html.mh-extra.com/html/nec/univerge-sl2100/univerge-sl2100_programming-manual_248294100.webp)
Item
No.
Item
Input Data
Description
Default
Related
Program
18
Call Forward Off-
Premise by Door-
phone
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
722
13-05
20
Record, Erase
VAU message
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
Define Service Code for VRS mes-
sage recording or erasing.
616
20-07-13
21
General message
play back (VRS)
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
611
20-07-14
22
Record and
Erase general
message (VRS)
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
612
20-07-15
23
Extension accu-
mulated printout
code
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
621
20-07-18
24
Group accumula-
ted printout code
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
622
20-07-19
25
Account Code
Accumulated
Printout Code
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
623
20-07-20
26
Forced trunk dis-
connect (Only
analogue trunk)
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
No Setting
20-07-11
27
Trunk port disa-
ble
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
645
20-07-12
32
Set Private Call
Refuse
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
646
14-01-27
20-07-24
33
Entry Caller ID
Refuse
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
647
20-07-25
34
Set Caller ID Re-
fuse
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
748
14-01-27
20-07-25
35
Dial-In Mode
Switching
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
609
20-07-26
41
Date Setting
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
789
20-07-30
42
Maintenance
Service
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
643
43
VRS Incoming
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
778
13-04
15-02-55
44
Cutting the tele-
phone power
0~9,
*
, # Maximum of
8 digit
Sets the Service Code for power
cutting. (for Administrator)
731
45
Remote Monitor
Permit Remote
Monitor Permit
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
Sets Service Code (SC) for Room
monitor on/off to terminal.
SC+1+Extension Number ; Room
Monitor enable
SC+0+Extension Number ; Room
Monitor disable
610
46
Watch Message
Setting
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
Service Code setting for Watching
message recording to VRS.
614
47
Warning Mes-
sage Setting
0~9,
*
, # Maximum of
8 digit
Terminal: MLT, SLT
Service Code setting for Warning
message recording to VRS.
615
48
Auto Dial Setting
for Sensor
0~9,
*
, # Maximum of
8 digit
Terminal: MLT
Service Code setting for destination
number when Warning mode detec-
ted.
617
SL2100
ISSUE 2.0
2-76
Program 11 : System Numbering
Program
11
Summary of Contents for UNIVERGE SL2100
Page 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Page 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Page 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Page 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Page 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Page 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Page 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Page 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Page 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Page 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Page 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Page 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Page 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Page 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...