Alarm
No.
Name
Item
No.01
de-
fault
Item
No.02
de-
fault
Content of
alarm
< generation
timing >
Cause
Measures
Recovery
Alarm
Status
29
Charge
manage-
ment buffer
full
0
0
The temporary
buffer for the
charge man-
agement in
main device
was overflow,
and a part of
unoutput
charge data
disappeared
because it was
not able to out-
put the charge
management
data.
<Operate it >
1.
The charge
data is printed
and not de-
leted at the
simple charge
management.
2.
The charge
data is not out-
put to PC for
the charge
management
software.
1.
Please print
and delete the
charge data at
the simple
charge man-
agement.
2.
Please con-
nect the
charge man-
agement soft-
ware for the
charge man-
agement soft-
ware and out-
put the charge
data.
When the
output is re-
started, the
error is re-
covered.
However,
the charge
manage-
ment data
after the er-
ror occurs is
not recor-
ded.
ERR
REC
30
SMDR buf-
fer full
2
0
The temporary
buffer for
SMDR in main
device was
overflow, and a
part of unoutput
SMDR data
disappeared
because it was
not able to out-
put SMDR da-
ta.
<Operate it >
1.
Problem of wir-
ing to connect
main device
with PC.
2.
Problem of
PC.
1.
Please confirm
whether there
is problem in
wiring to con-
nect a main
device with
PC.
2.
Please exe-
cute the reacti-
vation of PC.
When the
output is re-
started, the
error is re-
covered.
However,
the SMDR
data after
the error oc-
curs is not
recorded.
ERR
REC
31
Sensor Au-
to Dial
1
0
INF
32
Confirm Di-
al NoAns
1
0
INF
33
Reserved
1
0
34
Reserved
0
0
35
Reserved
0
0
36
Reserved
0
0
37
Reserved
0
0
38
Reserved
0
0
39
Reserved
0
0
40
Reserved
0
0
41
License
Name File
Load error
1
0
Can’t show Li-
cense Name,
because Sys-
tem fails to load
license name
file with system
boot up.
License Name File
is broken or file for-
mat is invalid.
Execute
PRG90-04-03 after
copy valid license
name file to SD
Card again.
Canceled
after valid li-
cense name
file is loa-
ded.
ERR
REC
42
4W termi-
nals does
not start
up.
2
0
308U or 008U
(WW) install to
Slot-4.
308U or 008U
(WW) install to
Slot-4.
Especially, anything
need not be done.
INF
43
2W termi-
nals does
not start
up.
2
0
082U install to
Slot-4.
082U install to
Slot-4.
Especially, anything
need not be done.
INF
44
Reserved
2
0
45
Reserved
0
0
SL2100
ISSUE 2.0
2-586
Program 90 : Maintenance Program
Program
90
Summary of Contents for UNIVERGE SL2100
Page 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Page 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Page 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Page 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Page 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Page 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Page 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Page 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Page 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Page 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Page 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Page 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Page 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Page 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...
Page 677: ...MEMO ISSUE 2 0 SL2100 Programming Manual 2 653 ...
Page 678: ...Programming Manual NEC Corporation ISSUE 2 0 ...