Item
No.
Item
Input Data
Description
Default
Related
Program
09
Caller ID Func-
tion
0 = Disable (Caller ID
not displayed.)
1 = Enable (Caller ID is
displayed.)
Enable (1) or disable (0) the Caller
ID FSK signal for an external Caller
ID module or a 3rd party vendor tel-
ephone with Caller ID display.
Important:
If voice mail is used, this setting
must be disabled for the system in-
tegration codes to be correct.
With a Single Line Telephone,
this must be set to 0 for incoming
callers to have a talk path.
0
10
Caller Name
0 = Disable
1 = Enable
Determine if an extension user tele-
phone should display the Caller
name.
1
15-03-09
12
Fixed Cadence
0 = Normal
1 = Fixed
1
13
MW sending type
0 = Lamp
1 = Caller ID
0
14
Forwarded Caller
ID Display Mode
0 = Calling Extension
Number (Calling)
1 = External Caller ID
(Forward)
Determine what the display shows
when a multiline terminal receives a
forwarded outside call.
0
15
Disconnect with-
out dial after
hooking hold
0 = Normal
1 = Disconnect
Determine whether or not to discon-
nect a held call when on-hook with-
out any dialing after hooking-hold.
0
16
Special DTMF
Protocol Send
0 = No
1 = Yes
Determine whether or not to send
the extension number of the phone
forwarded to the extension when
Program 15-03-04 is set to Special
(1) and not in the VM group.
0
45-01-16
18
Select Special
Terminal Type
0 = Fax
1 = Modem
This PRG is used for selecting Spe-
cial Terminal Type (Fax or Modem).
This setting influences how to trans-
mit data via SIP trunk. This PRG is
effective at the time of when
PRG15-03-03 1: Special.
0
15-03-03
19
Door Phone
Number
Do not set
the same
door phone
number as
PRG10-03-0
5 (SLIU).
1 ~ 6
Set the SLT door phone number.
When unlocking the door PRG10-61
will be in effect.
0
10-03-05
(SLIU)
10-61
SL2100
ISSUE 2.0
2-142
Program 15 : Extension, Basic Setup
Program
15
Summary of Contents for UNIVERGE SL2100
Page 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Page 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Page 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Page 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Page 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Page 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Page 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Page 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Page 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Page 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Page 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Page 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Page 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Page 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...
Page 677: ...MEMO ISSUE 2 0 SL2100 Programming Manual 2 653 ...
Page 678: ...Programming Manual NEC Corporation ISSUE 2 0 ...