Program 22 : Incoming Call Setup
22-01 : System Options for Incoming Calls
Level:
IN
Description
Use Program 22-01 : System Options for Incoming Calls
to define the system options for incoming
calls.
Input Data
Item
No.
Item
Input Data
Description
Default
Related
Program
01
Incoming Call
Priority
0 = Intercom Call Priori-
ty
1 = Trunk Call Priority
Use this option to determine if Inter-
com calls or trunk calls have answer
priority when both are ringing simul-
taneously.
1
15-02-22
02
Incoming Call
Ring No Answer
Alarm
0 = Disable (Off)
1 = Enable (On)
If enabled, an incoming call that
rings longer than the Ring No An-
swer Alarm interval (22-01-03),
changes to a unique ring cadence to
indicate that the call has been ring-
ing too long. If disabled, this does
not occur.
0
22-01-03
22-01-04
03
Ring No Answer
Alarm Time
0 ~ 64800 seconds
If a trunk rings a multiline telephone
longer than this interval, the system
changes the ring cadence. This indi-
cates to the user that the call has
been ringing too long.
60
22-01-02
04
DIL No Answer
Recall Time
0 ~ 64800 seconds
0 = No Overflow
A DIL that rings its programmed
destination longer than this interval
diverts to the DIL No Answer Ring
Group (set in Program 22-08).
0
06
DID Ring-No-An-
swer Time
0 ~ 64800 seconds
In systems with DID Ring-No-An-
swer Intercept, this sets the Ring-
No-Answer time. This time is how
long a DID call rings the destination
extension before rerouting to the in-
tercept ring group.
20
22-12
07
DID Incoming
Ring Group No
Answer Time
0 ~ 64800 seconds
20
08
DID Pilot Call No
Answer Time
0 ~ 64800 seconds
60
09
DID to Trunk to
Trunk no answer
timer
0 ~ 64800 seconds
20
10
VRS Waiting
Message Opera-
tion
0 = Automatic Opera-
tion
1 = Manual Operation
Set up the operation mode for Auto
Attendant and Queuing Message.
0
22-14
22-15
22-08
22-04
22-01-04
20-15-11
15-07
SL2100
ISSUE 2.0
2-284
Program 22 : Incoming Call Setup
Program
22
Summary of Contents for UNIVERGE SL2100
Page 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Page 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Page 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Page 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Page 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Page 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Page 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Page 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Page 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Page 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Page 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Page 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Page 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Page 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...
Page 677: ...MEMO ISSUE 2 0 SL2100 Programming Manual 2 653 ...
Page 678: ...Programming Manual NEC Corporation ISSUE 2 0 ...