Function
Number
Function
Additional Data
LED Indication
Note
77
Voice Mail (In-Skin)
Extension Number or
Pilot Number (8 dig-
its)
- IntraMail/InMail -
Fast Blink (Green)
: new message(s) in
own mailbox
Slow Blink (Red)
: new message(s) in
other mailbox
- APSU/external VM -
On (Red)
: Access to Voice Mail
Fast Blink (Green)
: new message(s) in
own mailbox
Slow Blink (Red)
: new message(s) in
other mailbox
78
In-skin Conversation
Recording
Fast Blink (Red) :
Recording
79
In-skin Automated At-
tendant
Extension Number or
Pilot Number (8 dig-
its)
Fast Blink
: Recording
80
Tandem Ringing Set Up
Key
Extension Number
On (Red) :
Master Side
Slow Blink (Red) :
Slave Side
81
Automatic Transfer to
Transfer Key
Trunk Line No. 1 ~
128
Off :
Cancel
Slow Blink (Red) :
Set
83
Conversation Recording
Function
0 = Pause
1 = Re-record
2 = Address
3 = Erase
4 = Urgent Page
84
Line Drop (send long
blink)
86
Private Call Refuse
None
Off
: pattern 1, pattern 5 ~ 8
On (Red)
: pattern 2
Slow Blink (Red)
: pattern 3
Fast Blink (Red)
: pattern 4
87
Caller ID Refuse
None
Off :
Cancel
Slow Blink (Red) :
Set
88
Dial-In Mode Switching
Program 22-17, Table
No. 1 ~ 500
Off :
pattern 1, pattern 5 ~ 8
On (Red) :
pattern 2
Slow Blink (Red) :
pattern 3
Fast Blink (Red) :
pattern 4
(125 msec
on/125 msec off/125 msec on/625
msec off) (Red)
90
Do-Not-Call Setup
92
Wake Up Call Indication None
93
Room Status Indication
None
94
Call Attendant
Fast Blink (Red) :
Setup - No answer
calls
(125 msec : on
⇒
125 msec : off
⇒
125
msec : on
⇒
625 msec : off) (Red) :
Setup - Busy calls
On (Red) :
Setup - Busy/No answer calls
95
Page Switching
None
On (Red) :
Buttons 1 ~ 60 are displayed.
Slow Blink (Red) :
Buttons 61 ~ 114 are
displayed.
The page
Switching Key
can be assigned
only between the
DSS key number
55-60.
97
Door Box Access Key
Doorphone No. (1 ~
6)
On (Red) :
Door Box Busy
Off :
Door Box Idle
Fast Blink (Red) :
Door Box Incoming
98
Message Waiting Indi-
cation Key
None
SL2100
ISSUE 2.0
2-348
Program 30 : DSS/DLS Console Setup
Program
30
Summary of Contents for UNIVERGE SL2100
Page 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Page 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Page 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Page 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Page 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Page 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Page 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Page 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Page 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Page 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Page 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Page 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Page 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Page 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...
Page 677: ...MEMO ISSUE 2 0 SL2100 Programming Manual 2 653 ...
Page 678: ...Programming Manual NEC Corporation ISSUE 2 0 ...