Program 22 : Incoming Call Setup
22-02 : Incoming Call Trunk Setup
Level:
IN
Description
Use
Program 22-02 : Incoming Call Trunk Setup
to assign the incoming trunk type for each trunk.
There is one item for each Night Service Mode.
Input Data
Trunk Port Number
1 ~ 128
Day/Night Mode
1 ~ 8
Item
No.
Item
Input Data
Description
Default
Related
Program
01
Trunk Service
Type
0 = Normal
1 = VRS (second dial
tone if no VRS instal-
led)
2 = DISA
3 = DID
4 = DIL
5 = Tie Line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID (DDI) Mode
Switching
Use this option to set the feature
type for the trunk you are program-
ming.
0
14-04
Conditions
• When connecting to T1 trunks, after changing Program 22-02-01 to match the Telco connected T1
service type, the T1 cable or the T1 board must be unplugged and then reconnected for the T1
board to sync.
• When the trunk type is set to 3 (DID), the DID Transfer to Destination in 22-11-04 for each DID
feature is not supported. This feature is supported only for DID trunks when assigned as VRS.
• When the trunk type is set to 3 (DID), the DID Intercept Destination feature for each DID is not
supported. This feature is supported only for DID trunks assigned as VRS.
Feature Cross Reference
• Central Office Calls, Answering
SL2100
ISSUE 2.0
2-286
Program 22 : Incoming Call Setup
Program
22
Summary of Contents for UNIVERGE SL2100
Page 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Page 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Page 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Page 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Page 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Page 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Page 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Page 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Page 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Page 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Page 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Page 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Page 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Page 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...
Page 677: ...MEMO ISSUE 2 0 SL2100 Programming Manual 2 653 ...
Page 678: ...Programming Manual NEC Corporation ISSUE 2 0 ...