5. Checking the Duplex State of Modules
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
48
Chapter 1 Maintenance
3. Select
Start – NEC ESMPRO Agent – ft server utility
to start the ft server utility.
4. On the left pane, select the primary PCI module as follows:
- Select
PCI module (ID:10)
when CPU/IO module 0 is primary module.
- Select
PCI module (ID:11)
when CPU/IO module 1 is a primary module.
5. Click
Down
of
Bring Up/Bring Down
Tips
When you stop the operation of the primary PCI module, a failover occurs and the
secondary PCI module becomes the primary module.
When the primary PCI module is stopped, the screen temporarily blacks out and then displayed again,
and the status changes as follows. This indicates that PCI module is failed over.
Indications of status LEDs
LED
Secondary*
Primary*
(1) PRIMARY LED
–
On (Green)
(2)
DISK ACCESS LED
–
Blinking amber or green
(Lights green when
accessing the disk drive)
LED
System
(3) System FT LED
–
* The primary and secondary modules after failover