Electra Elite IPK II
Document Revision 1
Electra Elite IPK II Programming Manual
2 - 547
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm is displayed to a multiline terminal and whether or not the alarm information
is reported to the pre-defined destination.
Default
Program 90 : Maintenance Program
90-10 : System Alarm Setup
Level:
IN
Input Data
Alarm Number
001~100
Item
No.
Item
Input Data
01
Alarm Type
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
02
Report
0 = Not Report (No autodial)
1 = Report (autodial)
Alarm
TYPE
Report
Note
Is Used To
Advise of . . .
Action
1
2 (Minor)
0
Board Initialization
Error
Initialization failure or
the ETU is defective.
Remove and reinstall
the ETU. If RECover
message is received
in the alarm report,
the ETU is good. If
not, replace with a
new ETU.
2
2 (MIN)
0
Board Initial Test
Error
ETU initial test failure
or the ETU is defective.
Remove and reinstall
the ETU. If RECover
message is received
in the alarm report,
the ETU is good. If
not, replace with a
new ETU.