Electra Elite IPK II
Document Revision 1
Electra Elite IPK II Programming Manual
2 - 321
Description
Use Program 32-03 : Door Box Basic Setup to select the chime pattern and gain
level for each Door Box. There are six distinctive chime patterns. The chime tones are
defined in Program 80-01.
The Door Box feature is referred to as “Door Phone” when programming via Web Pro
and using a Multiline Terminal.
Conditions
None
Feature Cross Reference
J
Door Box
Program 32 : Door Box and Sensor Setup
32-03 : Door Box Basic Setup
Level:
IN
Input Data
Door Box Number
1~8
Item
No.
Item
Input Data
Default
01
Chime Pattern
0
= None
1
= Door Box Ring 1
2
= Door Box Ring 2
3
= Door Box Ring 3
4
= Door Box Ring 4
5
= Door Box Ring 5
6
= Door Box Ring 6
Door Box 1 = 1
Door Box 2 = 2
Door Box 3 = 3
Door Box 4 = 4
Door Box 5 = 5
Door Box 6 = 6
Door Box 7 = 1
Door Box 8 = 1
02
CODEC Transmit Gain Setup
(PGD to Door Box)
1~63 (-15.5 ~ +15.5dB)
32
03
CODEC Receive Gain Setup
(Door Box to PGD)
1~63 (-15.5 ~ +15.5dB)
32