Program 21 : Outgoing Call Setup
08
Restriction Table
1~4 = Table
0
= Disable
(None)
0
Set the tables 1~4 when referring
to the table set up by 21-06-07.
21-06-07
09
Restriction for
Common Speed Dials
0
= Does Not
Restrict
1
= Following
Restriction
Check
0
Use this option to enable/disable
Toll Restriction for Common
Speed Dialing numbers. If
enabled, System Speed Dialing
numbers have the same
restrictions as manually dialed
numbers.
10
Restriction for Group
Speed Dials
0
= Does Not
Restrict
1
= Following
Restriction
Check
0
Use this option to enable/disable
Toll Restriction for Group Speed
Dialing numbers. If enabled,
Group Speed Dialing numbers
have the same restrictions as
manually dialed numbers.
11
Intercom Call
Restriction
0
= Disable
(No)
1
= Enable
(Yes)
0
It chooses whether ICM incoming
call is restricted.
12
PBX Call Restriction
0
= Disable
(No)
1
= Enable
(Yes)
0
Use this option to set how the
system Toll Restricts calls over
PBX trunks. If you enable PBX
Toll Restriction, the system begins
Toll Restriction after the PBX
access code. The user cannot dial
a PBX extension. If you disable
PBX Toll Restriction, the system
only restricts calls that contain the
PBX access code. The system
does not restrict calls to PBX
extensions. Refer to the PBX
compatibility feature. Make sure
Program 21-05-04 (Maximum
Number of Digits Table
Assignment) allows for PBX Toll
Call Dialing (normally 12 digits).
13
Restriction of Tie
Line Calls
0
= Disable
(No)
1
= Enable
(Yes)
0
It chooses whether the toll
restriction of the dial set up by 34-
08 is enabled or disabled.
34-08
14
Trunk Transfer
Restriction on
Incomplete Dial
0
= Not allow
1
= Allow
0 (Not allow)
If this program isset to “1”, you
can transfer the outgoing trunk
which you dialed incompletely.
15
Common Hold
Restriction on
Incomplete Dial
0
= Not allow
1
= Allow
0 (Not allow)
If this program is set to “1”, you
can hold the outgoing trunk which
you dialed in restriction check.
Item
No.
Item
Input Data
Default
Description
Related
Program
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ...PROGRAMMING MANUAL INT 1073 IPK II DOCUMENT REVISION 1 RELEASE 1000...
Page 3: ......
Page 5: ......
Page 7: ......
Page 616: ......
Page 617: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 1...