Document Revision 1
Electra Elite IPK II
2 - 16
Program 10 : System Configuration Setup
Description
Use Program 10-08 : Ringing Setup to enable or disable pre-ringing for trunk calls.
This sets how a trunk initially rings a telephone. With pre-ringing, a burst of ringing
occurs as soon as the trunk’s LED flashes. The call then continues ringing with the
normal ring cadence cycle. Without pre-ringing, the call starts ringing only when the
normal ring cadence cycle occurs. This may cause a ring delay, depending on when
call detection occurs in reference to the ring cycle.
Conditions
H
Used with Analog Trunks only.
Feature Cross Reference
J
Central Office Calls, Answering
J
Synchronous Ringing
Program 10 : System Configuration Setup
10-08 : Ringing Setup
Level:
IN
Input Data
Item
No.
Description
Input Data
Default
01
Ringing Setup
0 = Disable
1 = Enable
0