03
Number of Messages
(Number of Messages)
Use this option to set the maximum number of
messages that can be left in the Subscriber Mailbox.
If a caller tries to leave a message once this limit is
reached, they hear, “That mailbox is full.” IPK II
In-Mail then hangs up.
0~99 messages
To conserve storage
space, enter 0 for all
unused mailboxes.
99 messages for
mailbox 1
20 messages for
all other mailboxes
04
Message Playback
(Message Playback)
Use this option to set the Subscriber Mailbox
message playback order. When a subscriber listens
to their messages, IPK II In-Mail can play the oldest
messages first (first-in–first-out, or FIFO), or the
newest messages first (last-in–first-out, or LIFO).
0 (FIFO = first-in/
first-out, or oldest
messages first).
1 (LIFO = last-in/
first-out, or newest
messages first)
0 (FIFO = first-in/
first-out, or oldest
messages first)
05
Auto Erase/Save of Messages
(Auto Erase/Save)
Use this option to determine what happens when a
Subscriber Mailbox user completely listens to a new
message and then exits their mailbox without either
saving (SA) or erasing (E) the message. Depending
on the setting of this option, IPK II In-Mail will either
automatically save or erase the message. If the
mailbox user hangs up before listening to the entire
new message, IPK II In-Mail retains the message as
a new message.
0 (Erase)
After the subscriber
listens to the entire
new message and
hangs up, IPK II
In-Mail erases the
message.
1 (Save)
After the subscriber
listens to the entire
new message and
hangs up, IPK II
In-Mail saves the
message.
1 (Save)
06
Message Retention
(Message Retention)
Use this option to determine how long a Subscriber
Mailbox will retain held and saved messages. If a
message is left in a Subscriber Mailbox longer than
this interval, IPK II In-Mail deletes it.
1~90 Days
0 (Indefinite)
0 (Indefinite)
Input Data
Item
No.
Item
Input Data
Default
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ...PROGRAMMING MANUAL INT 1073 IPK II DOCUMENT REVISION 1 RELEASE 1000...
Page 3: ......
Page 5: ......
Page 7: ......
Page 616: ......
Page 617: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 1...