Program 12 : Night Mode Setup
Description
Use Program 12-02 : Automatic Night Service Patterns to define the daily pattern
of the Automatic Mode Switching. Each Mode Group has 10 patterns. These patterns
are used in Programs 12-03 and 12-04. The daily pattern consists of 20 timer settings.
Example:
Time Pattern 1
To make the above schedule, it is necessary to set the data as follows:
Program 12 : Night Mode Setup
12-02 : Automatic Night Service
Level:
SA
Input Data
Night Mode Service Group Number
01~32
Time Pattern Number
01~10
Set Time Number
01~20
Item
Description
Input Data
01
Start Time
0000~2359
02
End Time
0000~2359
03
Operation Mode
1~8
0:00
9:00
12:00
13:00
17:00
18:00
22:00
0:00
Mode 3
Mode 1
Mode 4
Mode 1
Mode 4
Mode 2
Mode 3
(midnight)
(day)
(rest)
(day)
(rest)
(night)
(midnight)
Time setting 01:
00:00 to 09:00
Mode 3 (midnight)
Time setting 02:
09:00 to 12:00
Mode 1 (day)
Time setting 03:
12:00 to 13:00
Mode 4 (rest)
Time setting 04:
13:00 to 17:00
Mode 1 (day)
Time setting 05:
17:00 to 18:00
Mode 4 (rest)
Time setting 06:
18:00 to 22:00
Mode 2 (night)
Time setting 07:
22:00 to 00:00
Mode 3 (midnight)