Program 14 : Trunk, Basic Setup
Description
Use Program 14-07 : Trunk Access Map Setup to set up the Trunk Access Maps.
This sets an extension’s access options for trunks. For example, an extension can
only place outgoing calls on trunks to which it has outgoing access. There are 200
Access Maps with all 200 trunk ports programmed in Map 1 with full access.
An extension can use one of the maps you set up in this program. Use Program 15-06
to assign Trunk Access Maps to extensions. Each trunk can have one of eight access
options for each Access Map.
Default
H
Access Map 1 = Trunk Ports 1~200 assigned with option ‘7’ access (incoming
and outgoing access and access when trunk is on Hold).
H
Access Maps 2~200 - Trunk Ports 1~200 assigned with option ‘0’ access (no
access).
Program 14 : Trunk, Basic Setup
14-07 : Trunk Access Map Setup
Level:
IN
Input Data
Access Map Number
001~200
Item
No.
Trunk Port
Number
Input Data
01
001~200
0 = No access
1 = Outgoing access only
2 = Incoming access only
3 = Access only when trunk on Hold
4 = Outgoing access and access when trunk on Hold
5 = Incoming access and access when trunk on Hold
6 = Incoming and Outgoing access
7 = Incoming access, outgoing access and access when trunk
on Hold