Document Revision 1
Electra Elite IPK II
2 - 32
Program 11 : System Numbering
the other codes are single digit. If you enter a two digit code between 0 and 9, be
sure to make separate entries for all the other two digit codes within the range as
well. This is because in the default program all the two digit codes between 0 and 9
are undefined.
Step 2: Specify the length of the code you want to change
After you specify a single or two digit code, you must tell the system how many digits
comprise the code. This is the Number of Digits Required column in the
System Numbering Default Settings on page 2-33
table. In the default program, all
codes from 100-999 are three digits long. Codes beginning with 0 are one digit long.
Codes beginning with
,
are 3 digits long and codes beginning with # are 4 digits long.
Step 3: Assign a function to the code selected
After entering a code and specifying its length, you must assign its function. This is
the Dial Type column in the
Table 2-2 System Numbering Default Settings on page
table. The choices are:
Dial
Types
Dial Type Description
Related Program
0
--- Not Used ---
1
Service Code
11-10 : Service Code Setup (for System Administrator)
11-11 : Service Code Setup (for Registration)
11-12 : Service Code Setup (for Service Access)
11-13 : Service Code Setup (for ACD)
11-14 : Service Code Setup (for HOTEL)
11-15 : Service Code Setup (Special access)
11-16 : Service Code Setup (Single Digit)
2
Extension Number
11-02 : Extension Numbers
11-04 : Virtual Extension Numbers
11-06 : PGD(2)-U10 (ACI) Extension Numbers
11-07 : Department Calling Group Numbers
11-08 : PGD(2)-U10 (ACI) Group Pilot Numbers
3
Trunk Access Code
11-09 : Trunk Access Code
4
Special Trunk Access
11-09 : Trunk Access Code
5
Operator Access
20-17 : Operator’s Extension
6
ARS/F-Route Access
44-xx
Changing the Dial Type for a range of codes can have a dramatic affect on how your system
operates. Assume, for example, the site is a hotel that has room numbers from 100-399. In order
to make extension numbers correspond to room numbers, you should use Program 11-02 to
reassign extension numbers on each floor from 100 to 399. (Other applications might also
require you to change entries in Program 11-10 through 11-16.)