Electra Elite IPK II
Document Revision 1
Electra Elite IPK II Programming Manual
2 - 445
03
Day of the Week
(Entryxx Day)
For Day of the Week (Type 1) Answer
Schedules, use this option to select the day of
the week the Answer Schedule should be
active.
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
1 (Sunday)
04
Start Day
(Entryxx Start Day)
For Range of Days (Type 2) Answer Schedules,
use this option to select the day of the week the
Answer Schedule should start.
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
1 (Sunday)
Answer Table 1/
Schedule 1 = 2
(Monday)
All Other
Schedules = 1
(Sunday)
05
End Day
(Entryxx End Day)
For Range of Days (Type 2) Answer Schedules,
use this option to select the day of the week the
Answer Schedule should end.
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
Answer Table 1/
Schedule 1 = 6
(Friday)
All Other
Answer
Schedules = 1
(Sunday)
06
Date
(Entryxx Date)
For Date (Type 3) Answer Schedules, use this
option to select the date the Answer Schedule
should be active.
MMDD
For example:
- 0101 = January 1
- 1231 = December 31
- 0000 = No date set
0000 = No Date
Set
07
Schedule Start Time
(Entryxx Start Time)
Use this option to specify the time the Answer
Schedule should start. It applies to Day of the
Week (Type 1), Range of Days (Type 2), and
Date (Type 3) schedules. (To make a schedule
run continuously, make the same entry for
47-12-07: Schedule Start Time and 47-12-08:
Schedule End Time.)
HHMM (24-hour clock)
For example:
- 0130 = 1:30AM
- 1700 = 5:00PM
Answer Table 1/
Schedule 1 =
08:30 (8:30AM)
All other
schedules are
undefined.
08
Schedule End Time
(Entryxx End Time)
Use this option to specify the time the Answer
Schedule should end. It applies to Day of the
Week (Type 1), Range of Days (Type 2), and
Date (Type 3) schedules. (To make a schedule
run continuously, make the same entry for
47-12-07: Schedule Start Time and 47-12-08:
Schedule End Time.)
HHMM (24-hour clock)
For example:
- 0130 = 1:30AM
- 1700 = 5:00PM
Answer Table 1/
Schedule 1 =
1700 (5:00PM).
All Other
Schedules =
0000
(Undefined).
Input Data (Continued)
Item
No.
Item
Input Data
Default
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ...PROGRAMMING MANUAL INT 1073 IPK II DOCUMENT REVISION 1 RELEASE 1000...
Page 3: ......
Page 5: ......
Page 7: ......
Page 616: ......
Page 617: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 1...