Document Revision 1
Electra Elite IPK II
2 - 542
Program 90 : Maintenance Program
Description
(This program is available only via telephone programming and not through PC
Programming).
Use Program 90-05 : Slot Control to reset or delete (uninstall) circuit boards (slots
1~24).
Delete allows you to completely uninstall the
ETU.
You might want to do this if you
want to remove an
ETU
and plug it into a different slot - and still retain the port
assignments. If a different type of interface ETU is being installed into a slot
previously used (e.g., changing from a SLI to an ESI
ETU)
, the slot should be deleted
(option 1) first before installing the new interface ETU.
Reset allows you to send a reset code.
Conditions
H
When you delete or reset a ETU, you must first remove it from its slot then run
Program 90-05. When reusing the slot for another ETU, you must plug the ETU in
or reset the system before the system will use the slot again.
Feature Cross Reference
None
Program 90 : Maintenance Program
90-05 : Slot Control
Level:
IN
Input Data
Menu Number
1 = Delete
2 = Reset
Item
No.
Item
Input Data
01
Slot Control
Slot Number (1~24)