Electra Elite IPK II Programming Manual
2 - 255
Program
24
Description
Use Program 24-01 : System Options for Hold to define the system options
for the Hold feature.
Program 24 : Hold/Transfer Setup
24-01 : System Options for Hold
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
Related
Program
01
Hold Recall Time
A call on Hold recalls the extension that
placed it on Hold after this interval. This
timer works with the Hold Recall
Callback Timer (Item 2).
0~64800 (sec)
90
02
Hold Recall Callback Time
A trunk recalling from Hold or Park rings
an extension for this interval. This timer
works with timer 01 (Hold Recall Time) or
timer 06 and 07 (Park Recall Time). After
this interval, the system invokes the Hold
recall time again. Cycling between timer
01 and 02 and 06 and 07 continues until
a user answers the call.
0~64800 (sec)
30
03
Exclusive Hold Recall Time
A call left on Exclusive Hold recalls the
extension that placed it on Hold after this
interval.
0~64800 (sec)
90
04
Exclusive Hold Recall Callback Time
An Exclusive Hold Recall rings an
extension for this interval. If not picked
up, the call goes back on System Hold.
0~64800 (sec)
30
05
Forced Release of Held Call
Depending on the setting of Program
14-01-16, the system disconnects calls
on Hold longer than this interval.
0~64800 (sec)
1800