Electra Elite IPK II
Document Revision 1
Electra Elite IPK II Programming Manual
2 - 257
Description
Use Program 24-02 : System Options for Transfer to define the system options for
the Transfer feature.
Program 24 : Hold/Transfer Setup
24-02 : System Options for Transfer
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
Related
Program
01
Busy Transfer
Use this option to prevent or allow extensions to
Transfer calls to busy extensions.
0
= Disable
(No)
1
= Enable
(Yes)
1
02
MOH or Ringback on Transferred Calls
Use this option to enable or disable MOH on
Transfer. If enabled (0), a transferred caller
hears MOH while their call rings the destination
extension. If disabled (1), a transferred caller
hears ringback while their call rings the
destination extension.
0
= Hold Tone
1
= Ring Back
Tone
0
20-03-02
03
Delayed Call Forwarding Time
If activated at an extension, Delayed Call
Forwarding occurs after this interval. This also
sets how long a Transferred call waits at an
extension forwarded to Voice Mail before routing
to the called extension’s mailbox.
0~64800 (sec)
10
04
Transfer Recall Time
An unanswered transferred call recalls to the
extension that initially transferred it after this
interval.
0~64800 (sec)
30
05
Message Wait Ring Interval Timer
For SLTs without message waiting lamps, this
timer determines the amount of time between
intermittent ringing. If this timer is set to '0' then
the system rings once.
0~64800 (sec)
30