Document Revision 1
Electra Elite IPK II
2 - 514
Program 84 : Hardware Setup for VoIP
Description
Use
Program 84-05 : VoIP Address Setup
to define the IP Address of the IP
Applications (MG16 ETU, CCISoIP ETU).
Program 84 : Hardware Setup for VoIP
84-05 : VoIP IP Address
Level:
IN
Input Data
Slot Number
01~24
Item
No.
Description
Input Data
Default
Related Program
01
IP Address
Set IP Address of IP
Application.
The IP Address will be
increased in
accordance with the
slot number.
1.0.0.1–126.255.255.254
128.1.0.1–191.254255.254
192.0.1.1–223.255.254.254
Slot 1: 172.16.0.20
Slot 2: 172.16.0.21
Slot 3: 172.16.0.22
Slot 4: 172.16.0.23
Slot 5: 172.16.0.24
Slot 6: 172.16.0.25
Slot 7: 172.16.0.26
Slot 8: 172.16.0.27
Slot 9: 172.16.0.28
Slot 10: 172.16.0.29
Slot 11: 172.16.0.30
Slot 12: 172.16.0.31
Slot 13: 172.16.0.32
Slot 14: 172.16.0.33
Slot 15: 172.16.0.34
Slot 16: 172.16.0.35
02
LAN Interface
NIC Auto Negotiation
0 = Auto Detect
1 = 100 Mbps, Full Duplex
2 = 100 Mbps, Half Duplex
3 = 10 Mbps, Full Duplex
4 = 10 Mbps, Half Duplex
0
03
Master/Slave
0 = Slave
1 = Master
0