Program
14
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for
each trunk port. Refer to the chart below for a description of each option, its
range and default setting.
Program 14 : Trunk, Basic Setup
14-01 : Basic Trunk Data Setup
Level:
IN
Input Data
Trunk Port Number
001~200
Item
No.
Item
Input Data
Default
Related
Program
01
Trunk Name
Set the names for
trunks. The trunk
name displays at the
display of a multiline
terminal for incoming
and outgoing calls.
Up to 12
Characters
Line 001
Line 002
Line 003
:
Line 200
02
Transmit Level
Use this option to
select the CODEC
gain for the trunk. The
option sets the
amount of gain (signal
amplification) for the
trunk you are
programming.
1~63
(-15.5 ~ +15.5dB
in 0.5dB intervals)
32 (0dB)
03
Receive Level
Use this option to
select the CODEC
gain for the trunk. The
option sets the
amount of gain (signal
amplification) for the
trunk you are
programming.
1~63
(-15.5 ~ +15.5dB
in 0.5dB intervals)
32 (0dB)