
Document Revision 1
Electra Elite IPK II
2 - 506
Program 82 : Basic Hardware Setup for Extension
Description
Use Program 82-11 : SLI Initial Setup to define the various timers for SLI Packages.
Conditions
None
Feature Cross Reference
None
Program 82 : Basic Hardware Setup for Extension
82-11 : SLI Initial Setup
Level:
IN
Input Data
Item
No.
Item
Description
Input
Default
01
Bounce Protect Time
Specify a time for detection of a
valid 0ff-Hook indication that is
long enough to prevent an
unintentional bounce of the
receiver from being detected as
a new Off-Hook indication from a
Single Line Telephone.
0 = No Setting
1~15 = 100ms~1.5sec
3
02
HookFlash Start Time
Specify the minimum hookflash
time from a Single Line
Telephone or analog Voice Mail
system before it is detected as
the beginning of a valid
hookflash.
0 = 40ms
1~15 = 90ms~790ms
5
03
HookFlash End Time
Specify the maximum hookflash
duration from a Single Line
Telephone to receive a second
dial tone.
0 = HST+0ms
1~15 =
HST+100ms~HST+1500ms
(HST=Hookflash Start Time)
7
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ...PROGRAMMING MANUAL INT 1073 IPK II DOCUMENT REVISION 1 RELEASE 1000...
Page 3: ......
Page 5: ......
Page 7: ......
Page 616: ......
Page 617: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 1...