Issue 6
Electra Elite
9 - 20
System Maintenance
F1
Low Volume Problems
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
1. Perform Second Initialization, and test.
2. Perform First Initialization, and test with
default program.
3. Replace CPUB( )-U10 ETU.
Problem
solved?
Done.
Replace COI(8)-U10 ETU.
Check line with dB
meter and/or contact
Telco.
Report Problem
to Telco.
Less than
-8 dB?
Line
Port
Reset or replace
COI(8)-U10, and
test again.
All lines?
Bridge on
system CO
line?
Remove it.
All stations?
Move suspected bad line to
good COI(8)-U10 ETU port.
Move good line to original
COI(8)-U10 ETU port.
Run a dB level test at DMARK
on lines with 1 kHz test tone.
No less than -8dB at MDF is
required.
Replace
Multiline SLT.
Problem
on port or
line?
Summary of Contents for Electra Elite 192
Page 2: ...SYSTEM HARDWARE MANUAL Stock Number 750363 Issue 6 Series 6000 192 ...
Page 3: ......
Page 5: ......
Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 10: ...Regulatory Information ...
Page 11: ......
Page 20: ......
Page 52: ...Issue 6 Electra Elite xxxii List of Tables THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ...Electra Elite Issue 6 System Hardware Manual 1 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 74: ...Issue 6 Electra Elite 1 22 Introduction ...
Page 96: ...Issue 6 Electra Elite 2 22 System Specifications ...
Page 104: ...Issue 6 Electra Elite 3 8 Hardware Requirements THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 213: ...Electra Elite Issue 6 System Hardware Manual 5 67 Figure 5 39 FMS 8 U10 ETU ...
Page 336: ...Issue 6 Electra Elite 7 54 Installing Optional Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 368: ...Issue 6 Electra Elite A 4 Glossary of Abbreviations THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 369: ...SYSTEM HARDWARE MANUAL NEC America Inc Issue 6 Series 6000 192 ...