Interdigital Time: 80 ms. default/70 ms. minimum
4.7
Battery Backup
The Electra Elite system has two battery backup functions: one for
system backup and one for memory backup.
4.7.1
System Backup
During power failure, the system is backed up using a
rechargeable battery. This battery backup supports all of
the system operations for approximately 30 minutes.
4.7.2
Memory Backup
The CPUB( )-U10 ETU has a battery installed to provide
backup of system memory. When the battery is fully
charged, system memory (customer data) is retained.
for approximately 21 days.
1209
1336
1477
697
1
2
3
770
4
5
6
852
7
8
9
941
,
0
#
Nominal High Group
Frequencies (Hz)
Nominal Low Group
Frequencies (Hz)
Summary of Contents for Electra Elite 192
Page 2: ...SYSTEM HARDWARE MANUAL Stock Number 750363 Issue 6 Series 6000 192 ...
Page 3: ......
Page 5: ......
Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 10: ...Regulatory Information ...
Page 11: ......
Page 20: ......
Page 52: ...Issue 6 Electra Elite xxxii List of Tables THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ...Electra Elite Issue 6 System Hardware Manual 1 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 74: ...Issue 6 Electra Elite 1 22 Introduction ...
Page 96: ...Issue 6 Electra Elite 2 22 System Specifications ...
Page 104: ...Issue 6 Electra Elite 3 8 Hardware Requirements THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 213: ...Electra Elite Issue 6 System Hardware Manual 5 67 Figure 5 39 FMS 8 U10 ETU ...
Page 336: ...Issue 6 Electra Elite 7 54 Installing Optional Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 368: ...Issue 6 Electra Elite A 4 Glossary of Abbreviations THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 369: ...SYSTEM HARDWARE MANUAL NEC America Inc Issue 6 Series 6000 192 ...