4.2
Cabling Precautions
4.2.1
Cable Placement
When selecting cables and Main Distribution Frame
(MDF), future expansion or assignment changes should
be considered. Avoid running cables in the following
places:
A place exposed to wind or rain.
A place near heat radiating equipment or where the
quality of station cable covering could be affected
by gases and chemicals.
An unstable place subject to vibration.
4.2.2
Environmental Conditions
Temperature
Operating:
+32°F ~ +104°F (0°C ~ 40°C)
Long Term:
+50°F ~ +90°F (10°C ~ 32.2°C)
Humidity
Operating:
10% ~ 90% noncondensing
4.3
Power Requirements
4.3.1
Power Supply Inputs
AC input requirements for the system are listed below.
AC Input (P64-U10 PSU)
117 Vac ± 10%
60 Hz ± 10%
Single Phase
7.5A circuit
A dedicated outlet, separately fused and grounded
Table 2-7 Zone Transceiver II Range
Connected Equipment
Range
ZT II-U Unit without ACA-U Unit
3,000 feet
ZT II-U Unit with ACA-U Unit
16,404 feet
Summary of Contents for Electra Elite 192
Page 2: ...SYSTEM HARDWARE MANUAL Stock Number 750363 Issue 6 Series 6000 192 ...
Page 3: ......
Page 5: ......
Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 10: ...Regulatory Information ...
Page 11: ......
Page 20: ......
Page 52: ...Issue 6 Electra Elite xxxii List of Tables THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ...Electra Elite Issue 6 System Hardware Manual 1 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 74: ...Issue 6 Electra Elite 1 22 Introduction ...
Page 96: ...Issue 6 Electra Elite 2 22 System Specifications ...
Page 104: ...Issue 6 Electra Elite 3 8 Hardware Requirements THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 213: ...Electra Elite Issue 6 System Hardware Manual 5 67 Figure 5 39 FMS 8 U10 ETU ...
Page 336: ...Issue 6 Electra Elite 7 54 Installing Optional Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 368: ...Issue 6 Electra Elite A 4 Glossary of Abbreviations THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 369: ...SYSTEM HARDWARE MANUAL NEC America Inc Issue 6 Series 6000 192 ...