Installing C.P. Components
8:25
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
07/01/04
Surface Remote Groundbed Configuration
In a remote groundbed, the anodes are placed in one location and the
current flows from them to the protected structure. This configuration is
typically used on transmission pipelines or in other places where there are
few other structures that might be affected by the current.
A typical surface point installation is illustrated in Figure 8.21.
+
_
Pipeline
Power
Source
Distance between the
structure and the anodes
is a remote distance.
Negative
Header
Cable
Impressed
Current
Anodes
Positive Header Cable
Figure 8.21 Surface Remote Groundbed Configuration
Distributed Anode Configuration
The distributed configuration is frequently used in complex areas to provide
good current distribution and to minimize effects on other structures. A
surface distributed groundbed is shown in Figure 8.22. Figure 8.23
illustrates a distributed impressed current bed protecting piling under a
wharf.