Installing C.P. Components
8:6
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
07/01/04
Test Box
Casing
Pipe
Casing Vent
Figure 8.4 Casing Test Station
Note that different color wires are used on the pipe and the casing. Here
again, it is essential that the color coding be exactly as shown on the design
drawings.
Two wires may be used on the casing, or the casing vent may serve as one
of the connections to the casing. The two connections to the casing and
carrier pipe are necessary to make casing-to-pipe resistance tests.
Foreign Line Crossing
Underground structures such as pipelines or cables frequently cross each
other or are in proximity to other facilities. Where one or both structures
have cathodic protection, there may be an interaction between the two. This
is called
cathodic interference
. To determine what effects are occurring and
to provide a facility to mitigate any undesirable effects, a foreign line test
station is installed. See Figure 8.5.