Stray Current Interference
6:10
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
02/01/05
Results
Experimental Step
Cathodically Protected
Structure Potentials (mV)
Foreign Structure
Potential (mV)
A B C D E F
Step 2
Step 5
Step 7 & 8
CONCLUSIONS
1.
Stray current pickup and a negative potential shift on the foreign
structure occurs at position F.
2.
Stray current discharge and a positive potential shift on the foreign
structure occurs at position D.
3.
The potentials on the cathodically protected structure are altered by the
presence of the foreign structure because the current distribution has
been disturbed.
Summary of Contents for CP 1
Page 1: ...CP 1 Cathodic Protection Tester Course Manual February 2005 NACE International 2000 ...
Page 265: ......
Page 266: ......
Page 267: ......
Page 268: ......
Page 301: ...RP0169 2002 32 NACE International ISBN 1 57590 035 1 ...
Page 535: ...TM0101 2001 24 NACE International ISBN 1 57590 137 4 ...