TM0497-2002
NACE International
7
5.11.2.3 Impressed current devices on foreign
piping; and
5.11.2.4 Numerous
cross
bonds
to
parallel
pipelines.
5.11.3 Natural and Manmade Stray Currents
5.11.3.1 Telluric currents; and
5.11.3.2 Manmade DC stray currents, such as
those from mass transit and mining operations.
5.12 When voltage drops have been evaluated at a test
location and the pipe-to-electrolyte potential found to be
satisfactory, the “on” pipe-to-electrolyte potential value may
be used for monitoring until significant environmental,
structural,
or
cathodic
protection
system
parameters
change.
5.12.1 Significant
environmental,
structural,
or
cathodic protection system parameter changes may
include:
(a) Replacement or addition of piping;
(b) Addition, relocation, or deterioration of cathodic
protection systems;
(c) Failure of electrical isolating devices;
(d) Effectiveness of coatings; and
(e) Influence of foreign structures
.
5.13 After a cathodic protection system is operating, time
may be required for the pipe to polarize. This should be
considered when measuring the potential at a test site on a
newly protected pipe or after reenergizing a cathodic
protection device.
________________________________________________________________________
Section 6: Causes of Measurement Errors
6.1 Factors
that
contribute
to
faulty
potential
measurements include:
6.1.1 Pipe and instrument test leads
(a)
Broken or frayed wire strands (may not be visible
inside the insulation);
(b)
Damaged or defective test lead insulation that
allows the conductor to contact wet vegetation, the
electrolyte, or other objects;
(c)
Loose, broken, or faulty pipe or instrument
connections; and
(d)
Dirty or corroded connection points.
6.1.2 Reference electrode condition and placement
(a)
Contaminated reference electrode solution or
rod, and solutions of insufficient quantity or saturation
(only laboratory-grade chemicals and distilled water, if
water is required, should be used in a reference
electrode);
(b)
Reference electrode plug not sufficiently porous
to provide a conductive contact to the electrolyte;
(c)
Porous plug contaminated by asphalt, oil, or
other foreign materials;
(d)
High-resistance
contact
between
reference
electrode
and
dry
or
frozen
soil,
rock,
gravel,
vegetation, or paving material;
(e)
Reference electrode placed in the potential
gradient of an anode;
(f)
Reference electrode positioned in the potential
gradient of a metallic structure other than the one with
the potential being measured;
(g)
Electrolyte between pipe and disbonded coating
causing error due to electrode placement in electrolyte
on opposite side of coating;
(h)
Defective
permanently
installed
reference
electrode;
(i)
Temperature
correction
not
applied
when
needed; and
(j)
Photo-sensitive measurement error (in CSE with
a clear-view window) due to light striking the electrode
electrolyte solution (photovoltaic effect).
6.1.3 Unknown isolating devices, such as unbonded
tubing or pipe compression fittings, causing the pipe to
be
electrically
discontinuous
between
the
test
connection and the reference electrode location.
6.1.4 Parallel path inadvertently established by test
personnel contacting instrument terminals or metallic
parts of the test lead circuit, such as test lead clips and
reference electrodes, while a potential measurement is
being made.
6.1.5 Defective or inappropriate instrument, incorrect
voltage range selection, instrument not calibrated or
zeroed, or a damp instrument sitting on wet earth.
6.1.6 Instrument having an analog-to-digital converter
operating at such a fast speed that the voltage spikes
produced by current interruption are indicated instead
of the actual “on” and “off” values.
6.1.7 Polarity of the measured value incorrectly
observed.
6.1.8 Cathodic protection current-carrying conductor
used as a test lead for a pipe potential measurement.
Summary of Contents for CP 1
Page 1: ...CP 1 Cathodic Protection Tester Course Manual February 2005 NACE International 2000 ...
Page 265: ......
Page 266: ......
Page 267: ......
Page 268: ......
Page 301: ...RP0169 2002 32 NACE International ISBN 1 57590 035 1 ...
Page 535: ...TM0101 2001 24 NACE International ISBN 1 57590 137 4 ...