Reference Cell Maintenance
Reference cells require attention if:
1.
The solution is cloudy or appears contaminated; or
2.
The copper rod is not bright and shiny; or
3.
Copper sulfate crystals are not visible; or
4.
When compared to a standard cell there is significant difference potential
Contaminated Cells
To restore reference electrodes for proper operation perform the following steps:
1.
Remove the reference cell tip, rod and end cap, and properly dispose of the
fluid contained in the cell.
2.
With non-metallic abrasive material (sandpaper), clean copper rod to a bright
and shiny condition.
3.
Re-assemble rod and end cap.