CHAPTER 5
Field Measurements
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
02/01/05
Other Portable Reference Electrodes
Silver-Silver Chloride Reference Electrode
Silver-silver chloride (Ag-AgCl) reference electrodes are used for
measurements in seawater. The Ag-AgCl electrode is also used in concrete
structures.
Calomel Reference Electrode
The saturated calomel reference electrode consists of mercury-mercurous
chloride in a saturated potassium chloride solution. This is primarily a
laboratory electrode.
Standard Hydrogen Reference Electrode (SHE)
The standard hydrogen reference electrode (SHE) is a laboratory reference
electrode and is used to determine the potential of other reference
electrodes that are better suited for field use.
Zinc Reference Electrode
Zinc is sometimes used as a reference electrode since the potential of zinc is
relatively stable. Zinc is actually a pseudo-reference electrode since the
potential of zinc can change as the environment changes.
For underground use, the zinc electrode is packaged in a cloth bag
containing the same backfill as used around zinc anodes. In water, zinc
electrodes are used bare.
Manganese Dioxide
The manganese dioxide electrode is also used in reinforced concrete
structures.
Graphite Electrode
Graphite is a pseudo-reference electrode that is sometimes used in
reinforced concrete structures.
Summary of Contents for CP 1
Page 1: ...CP 1 Cathodic Protection Tester Course Manual February 2005 NACE International 2000 ...
Page 265: ......
Page 266: ......
Page 267: ......
Page 268: ......
Page 301: ...RP0169 2002 32 NACE International ISBN 1 57590 035 1 ...
Page 535: ...TM0101 2001 24 NACE International ISBN 1 57590 137 4 ...