Field Measurements
5:13
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
02/01/05
Referring back to Figure 5.8, note that the positive lead from the meter is
connected to the left terminal of the shunt and the negative lead to the right
terminal. The figure shows an analog meter and note that the needle has
swung to the right from the left hand zero position. This indicates that
current flow is from left to right through the shunt.
Note also the battery and the direction of current flow around the circuit.
Current is leaving the positive terminal of the battery and proceeding
counter-clockwise around the circuit. Consequently, the current is flowing
from left to right through the shunt.
Various types of shunts and their values are shown in Table 5.2. The shunt
rating shown in the table is in amperes/millivolt.