RP0177-2000
NACE International
17
_______________________________________________________________________
Bibliography
CGA
(13)
Standard OCC-3-1981 (latest revision).
“Recommended Practice OCC-3-1981 for the
Mitigation of Alternating Current and Lightning
Effects on Pipelines, Metallic Structures, and
Corrosion Control Systems.” Toronto, Ontario,
Canada: Canadian Gas Association.
Gummow, R.A., R.G. Wakelin, and S.M. Segall. “AC
Corrosion
A New Challenge to Pipeline Integrity.”
CORROSION/98, paper no. 566. Houston, TX:
NACE, 1998.
Inductive Interference Engineering Guide. Murray Hills,
NJ: Bell Telephone Laboratories, March, 1974.
(Available through local Bell System Inductive
Coordinator.)
Lichtenstein, J. “AC and Lightning Hazards on Pipelines.”
Materials Performance 31, 12 (1992): pp. 19-21.
Lichtenstein, J. “Interference and Grounding Problems
on Metallic Structures Paralleling Power Lines.”
Western States Corrosion Seminar Proceedings.
Houston, TX: NACE, 1982.
Some Considerations During Construction Near
Powerlines (latest revision), NACE Audio/Visual
Presentation Prepared by Work Group T-10B-5a.
Houston, TX: NACE, 1983.
Wakelin, R.G., R.A. Gummow, and S.M. Segall. “AC
Corrosion
Case Histories, Field Testing and
Mitigation.” CORROSION/98, paper no. 565.
Houston, TX: NACE, 1998.
Westinghouse Transmission and Distribution Handbook.
Newark, NJ: Westinghouse Electric Corp., Relay-
Instrument Div., 1950.
_______________________________________________________________________
Appendix A: Wire Gauge Conversions
Table A1 provides the nearest metric size for the conductor sizes mentioned in this standard.
Table A1: Wire Gauge Conversions
Conductor Size
Diameter in mils
Nearest metric size
(mm
2
)
Diameter in mm of nearest
metric size
4,000 MCM
2,000
2,000
50.5
2,000 MCM
1,410
1,000
35.7
1,000 MCM
1,000
500
25.2
500 MCM
707
240
17.5
250 MCM
500
120
12.4
4/0 AWG
460
120
12.4
3/0 AWG
410
80
10.04
2/0 AWG
365
70
9.44
1/0 AWG
325
50
7.98
1 AWG
290
50
7.98
2 AWG
258
35
6.68
4 AWG
204
25
5.64
6 AWG
162
16
4.51
8 AWG
128
10
3.57
10 AWG
102
6
2.76
Source: Fink and Carroll, Standard Handbook for Electrical Engineers, 10th ed. (New York, NY: McGraw-Hill, 1968).
____________________________
(13)
Canadian Gas Association (CGA), 20 Eglinton Avenue West, Suite 1305, P.O. Box 2017, Toronto, ON M4R 1K8 CANADA.
Summary of Contents for CP 1