2-27
Setting Initial Operating Parameters
iControl AC
2
Critical TORQMAX F5 Drive Parameters (continued)
Motor Data
Induction Motor
• LM01 Motor Power
Job Specific
• LM02 Motor Speed
Job Specific
• LM03 Motor Current
Job Specific
• LM04 Motor Frequency
Job Specific
• LM05 Motor Voltage
Job Specific
• LM06 Motor Power Factor Job Specific (if unknown): 0.9 for high slip motors
0.75 for induction motors
• LM08 Electric Motor Protection 1 = On
• LM09 Motor Protection Current Job Specific
Motor Data
Permanent Magnet Motor
• LM02 Motor Speed
Job Specific
• LM03 Motor Current
Job Specific
• LM04 Motor Frequency
Job Specific
• LM05 Motor Voltage
Job Specific
• LM07 Motor Torque
Job Specific
• LM08 Motor Protection
1 = oN
• LM11 Peak Current Factor Job Specific
Encoder Data
• LE02 Encoder 1 Pulse Number
Job Specific
• LE03 Swap Encoder 1 Channels
Job Specific (Initially set to 0)
0 = Not Inverted
1 = A-B Swapped
2 = Inverted Rotation
3 = A-B Swap & Inverted Rotation
• LE04 Sample Rate for Encoder 3 = 4 msec
• LE05 Encoder 1 Multiplier Job Specific (no affect for incremental)
2 for Geared, 8 for Gearless
Machine Data
• LN01 Sheave Diameter
Job Specific
• LN02 Gear Ratio
Job Specific (See LN05 for the estimated value)
• LN03 Roping Ratio
Job Specific
Tune Parameters
Induction Motor
• LL01 Motor Tuning
Perform after all parameters are initially set
• LL07 Encoder Synchronization Perform after motor tuning - LL01