9-39
TORQMAX F5 Drive v3.xx Parameters Table
iControl AC
9
DG20 Raw Pattern
-
-
-10.00-
10.00
VDC
0.00
DG21
Processed
Pattern
-
-
-10.00-
10.00
VDC
0.00
DG30 Peak DC Volts
-
-
0-1500
Volts
0
DG31 Peak Current
-
-
-3200.0-
3200.0
Amps
0.0
DG32 Peak Speed
-
-
0-2500
ft/min
0
DG33 Raw Pretorque -
-
-10.00-
10.00
VDC
0.00
DG34 Post Pretorque -
-
-10.00-
10.00
VDC
0.00
DG35
Analog
Output 1
-
-
-10.00-
10.00
VDC
0.00
DG36
Analog
Output 2
-
-
-10.00-
10.00
VDC
0.00
DG37 Heatsink
Temperature
-
-
0-120
Degree
Celsius
0
DG38
Motor
Temperature
-
-
0: T1-T2
Closed-150
Degree
Celsius
0
DG39
Carrier
Frequency
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
0
1
2
3
4
2
kHz
0
DG40 Electric Power
-
-
-320.0-
320.0
kW
0.0
DG41 Motor Power
-
-
-320.0-
320.0
kW
0.0
DG42 Braking Energy -
-
0-65535
kWh
0
DG43 Power On
Counter
-
-
0-65535
hr
0
DG44
Run Time
Counter
-
-
0-65535
hr
0
DG45
Overload
Counter
-
-
0-100
%
0
DG46 Drive Load
-
0-500
%
0
DG47 Peak Load
-
-
0-500
%
0
DG50 Elevator Speed -
-
0-2000
ft/min
0
DG51 Mode
See Section 6.16
-
0
-
0
DG52 Active Profile
None
Inspection
High Speed
One Floor
Emergency
Correction
Emergency Slowdown
0
1
2
4
8
16
32
0
-
0
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para.
Name
Setting
Num
Range
Units
Default
Field