8-32 Manual # 42-02-2223
Using iView
Table 8.10 System - Configuration Tabs
Tab
Sub-Tab
Content
Emergency
Power
Use to indicate cars connected to each generator and define how switching
to and from emergency power is handled.
System
Configuration
Building
Floor definition and labeling. Car definition and labeling.
CFSS
Definition of Commandeer For Special Services modes 1 and 2.
Dispatching
Define system dispatching options and manually select dispatching config-
urations
Hall Call
Eligibility
Define up to eight Hall call eligibility configurations.
Mode of
Operation
Define up to eight dispatching Mode of Operation configurations.
Parking
Define up to eight Parking configurations.
Parking
Eligibility
Define up to eight Parking Eligibility configurations.
Split Bank
This capability is only available through the Central Dispatcher.
Management Controls Remote Monitoring Authorization and Local Dispatcher - Resend
system parameters command
.
Destination
Based
Dispatching
Enable DBD, set general DBD parameters, Destination Input Device param-
eters, Hallway configuration and special operations configuration parame-
ters.
Legacy Group
Interface
Select either Cross-cancellation or Cross-registration.
Security
General
Shows the status of System Security. Use these controls to configure car
and hall call restrictions for a simplex or swing car or car assigned to be the
backup or local dispatcher for a group.
Hall Calls
Car Calls
System I/O
System
Configuration of system input/output settings.
Bus
Serial bus troubleshooting.
Timer Tables
Use to configure timer tables to control system functions, e.g., Hall call eli-
gibility, Parking, Parking eligibility, Mode of operation, Security, and User
outputs 1 through 3.
User Events
Define User Events which, when assigned a hardware input, are logged on
the System Event Log when activated and deactivated.
Remote Outputs
Configuration Define and configure up to 32 Remote Outputs which can be wired to any
input or other device as needed.
Trigger
Predictive Gongs
Parameters determine the behavior of predictive gongs.
Table 8.11 System - Diagnostic Tabs
Tab
Content
Event Log
Display of recorded system events.
Network Diagnostics
Controller and Remote Client network information
.
DBD Call Diagnostics
Destination Based Dispatching call diagnostics tool.
Table 8.12 System - Miscellaneous Dialogs/Controls
Tab
Content
Call
Registration
Allows you to register car and hall calls. This control is accessed by clicking the Call
Registration button on the button bar.
Summary of Contents for Nidec iControl
Page 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Page 15: ......
Page 23: ...1 8 Manual 42 02 2223 iControl Overview...
Page 75: ...2 52 Manual 42 02 2223 Construction Mode...
Page 89: ...3 14 Manual 42 02 2223 Inspection Mode...