9-73
TORQMAX F5 Drive v1.xx Parameters Quick Refer-
iControl AC
9
Digital
Operator
Display
Parameter Description
Unit
Setting
Range
Default
Setting
Factory
Setting
LF.38
Carrier frequency; 0= 8 KHz, 1= 16KHz
(
Note: set LF.38 = 0 if E.OL2 error on drive
)
1
0, 1
0
*_________
LF.41
Leveling speed (Not used, must be set to 0)
fpm
0 - 25
0.0
0.0
LF.42
High speed
fpm
0 - LF.20
0.0
*________
LF.43
Inspection speed (Not used, must be set to 0)
fpm
0 - 150.00
0.0
0.0
LF.44
High leveling speed (Not used, must be set to 0)
fpm
-
0.0
0.0
LF.45
Earthquake speed (Not used, must be set to 0)
fpm
-
0.0
0.0
LF.46
Emerg. power Speed (Not used, must be set to 0) fpm
-
0.0
0.0
LF.47
Intermediate speed (Not used, must be set to 0)
fpm
-
0.0
0.0
LF.49
Over Speed Function Test: speed setting for Over
Speed Test Function (see LF.3 - OStST). ****
fpm
1 - 2400
100
100
Note:
Parameters LF.50 through LF.56 default to oFF when LF. 2 is set to AbSPd, A Spd or A Tor.
0.LF.50
Profile 0 - Starting jerk (Not used)
ft/s
3
see note
see note
oFF
0.LF.51
Profile 0 - Acceleration (Not used)
ft/s
2
see note
see note
oFF
0.LF.52
Profile 0 - Deceleration jerk (Not used)
ft/s
3
see note
see note
oFF
0.LF.53
Profile 0 - Deceleration jerk (Not used)
ft/s
2
see note
see note
oFF
0.LF.54
Profile 0 - Deceleration jerk (Not used)
ft/s
3
see note
see note
oFF
0.LF.55
Profile 0 - Approach jerk (Not used)
ft/s
3
see note
see note
oFF
1.LF.50
Profile 1 - Starting jerk (Not used)
ft/s
3
see note
see note
oFF
1.LF.51
Profile 1 - Acceleration (Not used)
ft/s
2
see note
see note
oFF
1.LF.52
Profile 1 - Deceleration jerk (Not used)
ft/s
3
see note
see note
oFF
1.LF.53
Profile 1 - Deceleration jerk (Not used)
ft/s
2
see note
see note
oFF
1.LF.54
Profile 1 - Deceleration jerk (Not used)
ft/s
3
see note
see note
oFF
1.LF.55
Profile 1 - Approach jerk (Not used)
ft/s
3
see note
see note
oFF
2.LF.50
Profile 2 - Starting jerk (Not used)
ft/s
3
see note
see note
oFF
2.LF.51
Profile 2 - Acceleration (Not used)
ft/s
2
see note
see note
oFF
2.LF.52
Profile 2 - Deceleration jerk (Not used)
ft/s
3
see note
see note
oFF
2.LF.53
Profile 2 - Deceleration jerk (Not used)
ft/s
2
see note
see note
oFF
2.LF.54
Profile 2 - Deceleration jerk (Not used)
ft/s
3
see note
see note
oFF
2.LF.55
Profile 2 - Approach jerk (Not used)
ft/s
3
see note
see note
oFF
LF.56
Stop jerk (Not used)
ft/s
3
see note
see note
oFF
LF.57
Speed following error (0 = off, 1 = on)
-
off, on
on
on
LF.58
Speed difference
%
0 - 30
10
10
LF.59
Trigger time speed difference: Following error
timer
sec
0.0 -1.0
1.0
1.0
LF.61
Emergency operation mode
-
off
off
LF.67
Pretorque gain
-
0.25 - 2.00
1.00
1.00
LF.68
Pretorque offset
%
-100 - 100
0.00
0.00
LF.69
Pretorque direction (-1 = -V, 1 = +V)
1
-1, 1
1
1
LF.70
Speed pick delay (Delay to turn on DRO).
sec
0.00 - 3.00
0.30
0.30
LF.71
Brake pick delay
sec
0.0 - 3.0
0.05
0.05
LF.76
Encoder resolution multiplier
2 for incremental encoder
8 for Sin/Cos, EnDat or Hiperface encoder
1
0 - 13
2
LF.77
Absolute encoder position (measured)
1
0 - 65535h
0
0
Table 9.1 TORQMAX F5 Drive Parameters Quick Reference for iControl AC
Summary of Contents for Nidec iControl
Page 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Page 15: ......
Page 23: ...1 8 Manual 42 02 2223 iControl Overview...
Page 75: ...2 52 Manual 42 02 2223 Construction Mode...
Page 89: ...3 14 Manual 42 02 2223 Inspection Mode...