6-87
iControl Circuit Board Quick References
iControl AC
6
Table 6.1 ICE-CTP-2 Board Connections
Terminal
Description
1
Common
DLSP
Door Logic Supply (See job prints for source level)
2
120VAC
DOF
Door Open Function output (active level =DLSP)
DBF
Door Boost Function output (active level =DLSP)
DCF
Door Close Function output (active level =DLSP)
NUDG
Door Nudge output (active level =DLSP)
SP1
Spare Input (120VAC signal level)
SP2
Spare Input (120VAC signal level)
SP3
Spare Input (120VAC signal level)
IMP_RST
Reset from ICE-IMP board
SE
(Door) Safe Edge Input (120VAC signal level)
PHE
Photo Eye input (120VAC signal level)
DOL
Door Open Limit input (120VAC signal level)
DCL
Door Close Limit input (120VAC signal level)
DPM
Door Position Monitor input (120VAC signal level)
ICTD
Cartop inspection down button (110VDC= switch closed)
ICTU
Cartop inspection up button (110VDC= switch closed)
INCT
Cartop inspection switch active (110VDC= switch closed)
GS
Gate Switch input (110VDC= switch closed)
GS-R
Gate Switch Rear (110VDC= switch closed)
ULM-R
Up Level Marker Rear output (110VDC= output active)
DZ-R
Door Zone Rear (110VDC= output active)
DLM-R
Down Level Marker Rear (110VDC= output active)
ULM
Up Level Marker (110VDC= output active)
DZ
Door Zone (110VDC= output active)
DLM
Down Level Marker (110VDC= output active)
1
Common
2
120VAC
3
110VDC
SCT1
Cartop Safety Contact 1 (110VDC= contact closed)
SCT2
Cartop Safety Contact 2 (110VDC= contact closed)