9-47
Magnetek HPV900 Series 2 Parameters Quick Ref-
iControl AC
9
Accel Jerk in 0
Rate of increase in acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0
0.00
0.00
Accel Jerk out 0
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0
0.00
0.00
Decel Jerk in 0
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0
0.00
0.00
Decel Jerk out 0
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0
0.00
0.00
Accel Rate 1
Acceleration rate #1
ft/s
2
0 - 7.99
3.00
Decel Rate 1
Deceleration rate #1
ft/s
2
0 - 7.99
3.00
Accel Jerk in 1
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0
8.0
Accel Jerk out 1
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0
8.0
Decel Jerk in 1
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0
8.0
Decel Jerk out 1
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0
8.0
Accel Rate 2
Acceleration rate #2
ft/s
2
0 - 7.99
3.00
Decel Rate 2
Deceleration rate #2
ft/s
2
0 - 7.99
3.00
Accel Jerk in 2
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0
8.0
Accel Jerk out 2
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0
8.0
Decel Jerk in 2
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0
8.0
Decel Jerk out 2
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0
8.0
Accel Rate 3
Acceleration rate #3
ft/s
2
0 - 7.99
3.00
Decel Rate 3
Deceleration rate #3
ft/s
2
0 - 7.99
3.00
Accel Jerk in 3
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0
8.0
Accel Jerk out 3
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0
8.0
Decel Jerk in 3
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0
8.0
Decel Jerk out 3
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0
8.0
A3 Multistep Ref
Speed Command 1 Multi-Step Speed command #1
ft/m
0
Speed Command 2 Multi-Step Speed command #2
ft/m
0
Speed Command 3 Multi-Step Speed command #3
ft/m
0
Speed Command 4 Multi-Step Speed command #4
ft/m
0
Speed Command 5 Multi-Step Speed command #5
ft/m
0
Speed Command 6 Multi-Step Speed command #6
ft/m
0
Table 9.7 Magnetek AC Drive Parameters Table
#
Operator
Display
Parameter Description
Unit
Setting
Range
MCE
Defaults
Field
Setting
Summary of Contents for Nidec iControl
Page 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Page 15: ......
Page 23: ...1 8 Manual 42 02 2223 iControl Overview...
Page 75: ...2 52 Manual 42 02 2223 Construction Mode...
Page 89: ...3 14 Manual 42 02 2223 Inspection Mode...